Towards Improved Field Application of Using Distributed Temperature Sensing for Soil Moisture Estimation: A Laboratory Experiment

Sensors (Basel). 2019 Dec 19;20(1):29. doi: 10.3390/s20010029.

Abstract

The "dual probe heat pulse" (DPHP) method using actively heated fiber optic (AHFO) cables combined with distributed temperate sensing (DTS) technology has been developed for monitoring thermal properties and soil water content at the field scale. Field scale application, however, requires the use of robust and thicker fiber optic cables, corroborating the assumption of an infinite thin heat source in the evaluation process. We therefore included a semi-analytical solution of the heat transport equation into the evaluation procedure in order to consider the finite thermal properties of the heating cable without a calibration procedure to estimate effective thermal properties of the soil. To test this new evaluation procedure, we conducted a laboratory experiment and tested different heating scenarios to infer soil moisture from volumetric heat capacity. Estimates were made by analyzing the shift of the temperature amplitude at the sensing cable and the characteristics of the response heating curve. The results were compared with results from the calibrated infinite line source solution and in situ water content point measurements and showed a good approximation of thermal properties for strong and short heat pulses. Volumetric water content estimates are similarly accurate to the results of the calibrated infinite line source solution. Problems arose with the cable spacing and the resettlement process after burying the cable.

Keywords: actively heated fiber optics; distributed temperate sensing; dual probe heat; field application; soil thermal properties; soil water content.