Background: The optimal dosage for cryoablation of atrial fibrillation (Cryo-AF) is still unknown. To evaluate the efficacy of an individualized freeze duration, we compared the clinical outcome of patients treated with a time-to-pulmonary vein isolation (TT-PVI) or temperature-guided ablation protocol to the outcome of patients treated with a conventional ablation protocol.

Methods: A total of 164 consecutive patients were included in the study. One method employed was a conventional dosing protocol (at least 2 applications of 180 s each) (the Cryo-AFConventional group n = 84), and the second method had a shorter protocol that was based on the TT-PVI or achievement of - 40 °C within 60 s (the Cryo-AFDosing group n = 80) RESULTS: We treated 656 pulmonary veins (PVs) with 1420 cryotherapy applications. The mean number of applications per patient was 8.7 ± 0.8, with no difference between groups (Cryo-AFConventional, 8.7 ± 0.8 versus Cryo-AFDosing,8.6 ± 0.8; P = 0.359). The Cryo-AFDosing group required significantly less total cryotherapy application time (990.60 ± 137.77versus 1501.58 ± 89.60 s; P < 0.001) and left atrial dwell time (69.91 ± 6.91 versus 86.48 ± 7.03 min; P < 0.001) than the Cryo-AFConventional group. Additionally, the Cryo-AFDosing group required significantly less total procedure time (95.03 ± 6.50 versus 112.43 ± 7.11 min; P < 0.001). We observed acute ATP-induced or spontaneous vein electric reconnections in 13 veins (1.98%) after 20 min. The reconnection rates between the Cryo-AFConventional and Cryo-AFDosing groups were similar in that 2.98 and 0.94% of the initially isolated veins were reconnected, respectively, (P = 0.061). There was no difference in the recurrence rate of free atrial arrhythmia after a 1-year follow-up, which were 78.75% in the Cryo-AFDosing group versus 78.57% in the Cryo-AFConventional group (P = 0.978).

Conclusion: A novel Cryo-AF dosing protocol guided by temperature or the TT-PVI can be used to individualize an ablation strategy. This new protocol can lead to a significant reduction in duration of the procedure, the cryoenergy dosage and the left atrial dwell time. The procedure had equal safety and similar acute and 1-year follow-up outcomes compared to the conventional approach.

Keywords: Atrial fibrillation; Catheter ablation; Cryoablation; Cryoballoon; Dosing.

Publication types

  • Clinical Trial
  • Comparative Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Action Potentials
  • Aged
  • Atrial Fibrillation / diagnosis
  • Atrial Fibrillation / physiopathology
  • Atrial Fibrillation / surgery*
  • Catheter Ablation* / adverse effects
  • Clinical Decision-Making
  • Cryosurgery* / adverse effects
  • Female
  • Heart Rate
  • Humans
  • Male
  • Middle Aged
  • Prospective Studies
  • Pulmonary Veins / physiopathology
  • Pulmonary Veins / surgery*
  • Time Factors
  • Treatment Outcome