Probeless non-invasive near-infrared spectroscopic bioprocess monitoring using microspectrometer technology

Anal Bioanal Chem. 2020 Apr;412(9):2103-2109. doi: 10.1007/s00216-019-02227-w. Epub 2019 Dec 4.

Abstract

Real-time measurements and adjustments of critical process parameters are essential for the precise control of fermentation processes and thus for increasing both quality and yield of the desired product. However, the measurement of some crucial process parameters such as biomass, product, and product precursor concentrations usually requires time-consuming offline laboratory analysis. In this work, we demonstrate the in-line monitoring of biomass, penicillin (PEN), and phenoxyacetic acid (POX) in a Penicilliumchrysogenum fed-batch fermentation process using low-cost microspectrometer technology operating in the near-infrared (NIR). In particular, NIR reflection spectra were taken directly through the glass wall of the bioreactor, which eliminates the need for an expensive NIR immersion probe. Furthermore, the risk of contaminations in the reactor is significantly reduced, as no direct contact with the investigated medium is required. NIR spectra were acquired using two sensor modules covering the spectral ranges 1350-1650 nm and 1550-1950 nm. Based on offline reference analytics, partial least squares (PLS) regression models were established for biomass, PEN, and POX either using data from both sensors separately or jointly. The established PLS models were tested on an independent validation fed-batch experiment. Root mean squared errors of prediction (RMSEP) were 1.61 g/L, 1.66 g/L, and 0.67 g/L for biomass, PEN, and POX, respectively, which can be considered an acceptable accuracy comparable with previously published results using standard process spectrometers with immersion probes. Altogether, the presented results underpin the potential of low-cost microspectrometer technology in real-time bioprocess monitoring applications. Graphical abstract.

Keywords: Bioprocess monitoring; In-line; Microspectrometer; Near-infrared; Non-invasive; P. chrysogenum.

MeSH terms

  • Acetates / analysis
  • Acetates / metabolism*
  • Batch Cell Culture Techniques / instrumentation
  • Batch Cell Culture Techniques / methods
  • Biomass
  • Bioreactors
  • Equipment Design
  • Fermentation
  • Least-Squares Analysis
  • Penicillins / analysis
  • Penicillins / metabolism*
  • Penicillium chrysogenum / chemistry
  • Penicillium chrysogenum / growth & development
  • Penicillium chrysogenum / metabolism*
  • Spectroscopy, Near-Infrared / instrumentation
  • Spectroscopy, Near-Infrared / methods*

Substances

  • Acetates
  • Penicillins
  • phenoxyacetic acid