Early clinical and procedural outcomes in large series of 34-mm self-expanding transcatheter aortic valve replacement

Catheter Cardiovasc Interv. 2020 Oct 1;96(4):940-946. doi: 10.1002/ccd.28634. Epub 2019 Dec 4.

Abstract

Objectives: We aimed to evaluate early clinical and procedural outcomes with the 34-mm Evolut R transcatheter aortic valve replacement (TAVR) prosthesis.

Background: The 34-mm Evolut R (Medtronic, Minneapolis, MN) self-expanding TAVR prosthesis was designed to treat patients with larger annuli.

Methods: Clinical, demographic, procedural, and echocardiographic data on consecutive patients who underwent TAVR with a 34-mm Evolut R prosthesis at our institution were collected and analyzed.

Results: One hundred ninety-six patients underwent TAVR with this prosthesis from November 2016 to July 2018, a majority (n = 188, 96%) through transfemoral access and with conscious sedation (n = 182, 93%). Mean age, Society of Thoracic Surgery risk score, and follow-up were 82 ± 8 years, 5.4 ± 5%, and 8.2 ± 5.3 months, respectively. Mean aortic valve (AV) peak velocity was 4.0 ± 0.6 m/s, mean AV gradient was 38 ± 13 mmHg, AV area was 0.79 ± 0.23 cm2 ; calcium score was 3,503 ± 1,970 Agatston units, and perimeter was 85 ± 4.3 mm. Device implantation was successful in all but one patient. Postprocedure mean AV peak velocity, AV mean gradient, and AV area were 1.9 ± 0.4 m/s, 7 ± 3 mmHg, and 2.6 ± 0.7 cm2 , respectively. New pacemaker requirement rate was 16%, and moderate paravalvular leak was present in six patients (3%), which improved to mild in three patients at 6-month follow-up. In-hospital, 30-day, 6-month, and 12-month survival rates were 98%, 96% (hospital discharge), 96% (30-day), 89% (6-month), and 83% (12-month).

Conclusion: These data demonstrate high success and good procedural, echocardiographic, and clinical outcomes of 34-mm Evolut R in patients with large annuli.

Keywords: 34 mm; TAVR; aortic stenosis; large annuli; paravalvular leak.

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Valve / diagnostic imaging
  • Aortic Valve / physiopathology
  • Aortic Valve / surgery*
  • Aortic Valve Stenosis / diagnostic imaging
  • Aortic Valve Stenosis / mortality
  • Aortic Valve Stenosis / physiopathology
  • Aortic Valve Stenosis / surgery*
  • Female
  • Heart Valve Prosthesis*
  • Hospital Mortality
  • Humans
  • Male
  • Postoperative Complications / mortality
  • Postoperative Complications / therapy
  • Prosthesis Design
  • Recovery of Function
  • Retrospective Studies
  • Risk Factors
  • Severity of Illness Index
  • Time Factors
  • Transcatheter Aortic Valve Replacement / adverse effects
  • Transcatheter Aortic Valve Replacement / instrumentation*
  • Transcatheter Aortic Valve Replacement / mortality
  • Treatment Outcome