Rapid, sensitive and simultaneous determination of 16 endocrine-disrupting chemicals (parabens, benzophenones, bisphenols, and triclocarban) in human urine based on microextraction by packed sorbent combined with liquid chromatography tandem mass spectrometry (MEPS-LC-MS/MS)

Chemosphere. 2020 Feb:240:124951. doi: 10.1016/j.chemosphere.2019.124951. Epub 2019 Sep 23.

Abstract

A high demand exists in human biomonitoring studies for reliable and straightforward methods that generate data faster and simultaneously. Thus, the present study combines microextraction by packed sorbent (MEPS) and liquid chromatography coupled to mass spectrometry (LC-MS/MS) for simultaneous extraction and determination of various classes of endocrine-disrupting chemicals (EDCs), including parabens, benzophenones, bisphenols, and the antimicrobial, triclocarban in human urine samples. Optimized MEPS conditions were: i) MEPS sorbent (C18), ii) pH of sample (3), iii) volume of sample (250 μL), iv) number of draws-eject cycles (5) and (vi) desorption solvent conditions (100 μL of CH3OH:H2O 80:20 v/v). The calibration curves were linear over the selected ranges for all studied compound, with correlation coefficients higher than 0.99. The variation coefficient for precision was lower than 20% at lower concentrations and lower than 15% at the higher concentrations studied. The accuracy ranged from 90% to 118%. The proposed strategy affords several advantages over currently published approaches, including simplicity of operation and reduction of sample and solvent volumes and time for matrix clean-up. Moreover, the analytical performance of each MEPS cartridge remained stable over the analysis of at least 70 samples (RSD < 10%). Thus, the current procedure may be an interesting high-throughput alternative for large routine human biomonitoring studies. Urinary geometric mean concentrations of EDCs obtained in this study were close than those previously reported for Brazilian children.

Keywords: Biomonitoring studies; Endocrine-disrupting chemicals; Human urine samples; Liquid chromatography-tandem mass spectrometry; Microextraction by packed sorbent.

MeSH terms

  • Benzhydryl Compounds / urine*
  • Benzophenones / urine*
  • Brazil
  • Calibration
  • Carbanilides / urine*
  • Child
  • Chromatography, High Pressure Liquid / methods
  • Chromatography, Liquid
  • Endocrine Disruptors / urine*
  • Humans
  • Limit of Detection
  • Parabens / analysis*
  • Phenols / urine*
  • Solid Phase Microextraction / methods
  • Tandem Mass Spectrometry / methods

Substances

  • Benzhydryl Compounds
  • Benzophenones
  • Carbanilides
  • Endocrine Disruptors
  • Parabens
  • Phenols
  • triclocarban
  • bisphenol A