Is Contrast Stasis After Pipeline Embolization Device Deployment Associated with Higher Aneurysm Occlusion Rates?

World Neurosurg. 2020 Jan:133:e434-e442. doi: 10.1016/j.wneu.2019.09.032. Epub 2019 Sep 13.

Abstract

Objective: To assess the association of degree of contrast stasis in intracranial aneurysms (IAs) immediately after Pipeline embolization device (PED; Medtronic, Dublin, Ireland) deployment with 6- and 12-month angiographic occlusion rates.

Methods: This retrospective cohort study included consecutive patients undergoing PED deployment for saccular IA treatment at a large-volume cerebrovascular center over a 4-year 9-month period. Angiographic images obtained immediately after PED deployment were graded according to amount of intra-aneurysmal contrast flow during the late venous phase: 0 = no stasis; 1 = <50% contrast stasis; 2 = 50%-75% stasis; and 3 = >75%-99% stasis. Follow-up occlusion rates were determined by digital subtraction angiography, computed tomographic angiography, or magnetic resonance angiography.

Results: The study included 119 patients in whom 182 PEDs were deployed to treat 141 aneurysms. A single PED was deployed in 105 (74.5%) aneurysms. The internal carotid artery was the commonest aneurysm site (119 [85%]). Fifty-two (36.9%) aneurysms were grade 0; 33 (23.4%) were grade 1; 46 (32.6%) were grade 2; and 10 (7.1%) were grade 3 immediately post-treatment. A 6-month follow-up angiogram available for 101 aneurysms showed complete occlusion (no flow into the aneurysm) in 74 (73.3%) aneurysms. A 12-month follow-up study available for 132 aneurysms showed complete occlusion in 79.5%. At last follow-up, occlusion rates were not significantly different for different contrast stasis grades (P = 0.60). Mean angiographic follow up for all IAs was 23v±v17.7 months. IA size, sex, age, and smoking were not significant predictors of occlusion.

Conclusions: The degree of aneurysm contrast stasis immediately after PED deployment is not statistically associated with 6- and 12-month angiographic occlusion rates.

Keywords: Aneurysm occlusion; Contrast stasis; Pipeline embolization device.

MeSH terms

  • Adult
  • Aged
  • Angiography, Digital Subtraction
  • Cerebral Angiography
  • Contrast Media / pharmacokinetics
  • Embolization, Therapeutic / instrumentation*
  • Embolization, Therapeutic / methods
  • Female
  • Follow-Up Studies
  • Hemorheology*
  • Humans
  • Intracranial Aneurysm / diagnostic imaging
  • Intracranial Aneurysm / therapy*
  • Male
  • Middle Aged
  • Retrospective Studies
  • Single-Blind Method
  • Stents*
  • Thrombosis / etiology
  • Treatment Outcome

Substances

  • Contrast Media