3D 31 P MR spectroscopic imaging of the human brain at 3 T with a 31 P receive array: An assessment of 1 H decoupling, T1 relaxation times, 1 H-31 P nuclear Overhauser effects and NAD

NMR Biomed. 2021 May;34(5):e4169. doi: 10.1002/nbm.4169. Epub 2019 Sep 13.

Abstract

31 P MR spectroscopic imaging (MRSI) is a versatile technique to study phospholipid precursors and energy metabolism in the healthy and diseased human brain. However, mainly due to its low sensitivity, 31 P MRSI is currently limited to research purposes. To obtain 3D 31 P MRSI spectra with improved signal-to-noise ratio on clinical 3 T MR systems, we used a coil combination consisting of a dual-tuned birdcage transmit coil and a 31 P eight-channel phased-array receive insert. To further increase resolution and sensitivity we applied WALTZ4 1 H decoupling and continuous wave nuclear Overhauser effect (NOE) enhancement and acquired high-quality MRSI spectra with nominal voxel volumes of ~ 17.6 cm3 (effective voxel volume ~ 51 cm3 ) in a clinically relevant measurement time of ~ 13 minutes, without exceeding SAR limits. Steady-state NOE enhancements ranged from 15 ± 9% (γ-ATP) and 33 ± 3% (phosphocreatine) to 48 ± 11% (phosphoethanolamine). Because of these improvements, we resolved and detected all 31 P signals of metabolites that have also been reported for ultrahigh field strengths, including resonances for NAD+ , NADH and extracellular inorganic phosphate. T1 times of extracellular inorganic phosphate were longer than for intracellular inorganic phosphate (3.8 ± 1.4s vs 1.8 ± 0.65 seconds). A comparison of measured T1 relaxation times and NOE enhancements at 3 T with published values between 1.5 and 9.4 T indicates that T1 relaxation of 31 P metabolite spins in the human brain is dominated by dipolar relaxation for this field strength range. Even although intrinsic sensitivity is higher at ultrahigh fields, we demonstrate that at a clinical field strength of 3 T, similar 31 P MRSI information content can be obtained using a sophisticated coil design combined with 1 H decoupling and NOE enhancement.

Keywords: 1H decoupling; 31P MR spectroscopic imaging; 3 T; T1; brain; nuclear Overhauser effect.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adenosine Triphosphate / metabolism
  • Adult
  • Brain / diagnostic imaging*
  • Female
  • Humans
  • Magnetic Resonance Spectroscopy*
  • Male
  • Metabolome
  • NAD / metabolism*
  • Phosphates / analysis
  • Phosphocreatine / analogs & derivatives
  • Phosphocreatine / metabolism
  • Phosphorus
  • Proton Magnetic Resonance Spectroscopy
  • Signal Processing, Computer-Assisted
  • Time Factors

Substances

  • Phosphates
  • Phosphocreatine
  • NAD
  • Phosphorus
  • phosphocreatinine
  • Adenosine Triphosphate