Physical Activity and Sedentary Behavior Assessment: A Laboratory-Based Evaluation of Agreement between Commonly Used ActiGraph and Omron Accelerometers

Int J Environ Res Public Health. 2019 Aug 28;16(17):3126. doi: 10.3390/ijerph16173126.

Abstract

Different models of accelerometer have the potential to provide a different estimate of the same physical activity or sedentary behavior. Our study compared the outputs of the Active Style Pro (ASP) and ActiGraph (AG) devices in assessing predicted metabolic equivalents (METs) for specific activities under laboratory conditions. Thirty healthy young adults wore two hip accelerometers (ASP and AG), simultaneously while performing twenty-two activities (eight sedentary, eight household, and six ambulatory activities) in a controlled laboratory setting. For the AG, predicted METs for each activity was calculated using four equations based on vertical-axis and vector magnitude data. Separate paired t-tests and Bland-Altman analysis examined the difference and agreement in METs between AG using four commonly used equations and ASP measurements for each activity. AG devices using different equations calculated significantly different outcomes for most activities compared with ASP devices. The smallest differences in predicted METs estimates between ASP and AG were observed for ambulatory activities. Ambulatory activities demonstrated the best agreement between ASP and AG regardless of which AG equation was used. Our findings can be used to assist researchers in their selection of accelerometer and output estimation equations for measuring physical activity and sedentary behavior in adults.

Keywords: accelerometer; activity monitor; measurement; objective assessment; physical activity.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Accelerometry / instrumentation*
  • Actigraphy / instrumentation*
  • Adult
  • Exercise*
  • Female
  • Humans
  • Male
  • Reproducibility of Results
  • Sedentary Behavior*
  • Young Adult