Complex effects of continuous vasopressor infusion on fluid responsiveness during liver resection: A randomised controlled trial

Eur J Anaesthesiol. 2019 Sep;36(9):667-675. doi: 10.1097/EJA.0000000000001046.

Abstract

Background: Fluid responsiveness is an important factor to consider for fluid volume loading during major surgery. The effect of continuous vasopressor infusion on fluid responsiveness during prolonged major surgery is a concern.

Objective: We hypothesised that continuous vasopressor infusion during major surgery might not exert significant effects on changes in stroke volume variation (SVV) following fluid bolus infusion, and thereby on fluid responsiveness.

Design: Randomised controlled trial.

Setting: University hospital from April 2014 to August 2016.

Patients: Patients undergoing liver resection who were randomised to receive continuous intravenous infusion of phenylephrine (P group), norepinephrine (N group), or no vasopressor (C group) (n=17/group). Exclusion criteria were cardiac arrhythmia and severe cardiac, pulmonary or renal dysfunction.

Intervention: Patients received 4 ml kg fluid boluses of 6% hydroxyethyl starch solution when SVV was at least 12%. Vasopressors were administered continuously to maintain the systemic vascular resistance index at more than 1900 dyn s cm m.

Main outcome measures: Cardiac index and SVV were measured using the FloTrac/Vigileo system (Version 4.00). The number of fluid boluses with fluid responsiveness (i.e. >15% increase in cardiac index) was compared between groups using multilevel logistic regression analysis.

Results: Numbers of fluid responsive boluses in the C, P and N groups were 12 (14%), 22 (34%) and 19 (27%), respectively. Odds ratios on fluid responsiveness for phenylephrine and norepinephrine compared with the control were 3.65 (97.5% confidence interval, 1.15 to 11.6; P = 0.012) and 2.56 (97.5% confidence interval, 0.82 to 8.00; P = 0.064), respectively. Decreases in SVV after fluid bolus infusion for the P and N groups were comparable with the C group (P = 0.23 and 0.53, respectively).

Conclusion: Continuous administration of phenylephrine increased fluid responsiveness during liver resection, suggesting complex effects of continuous vasopressor infusion involving changes in cardiac preload and afterload.

Trial registration: UMIN000011024.

Publication types

  • Randomized Controlled Trial

MeSH terms

  • Aged
  • Anesthesia, General / adverse effects
  • Anesthesia, General / methods
  • Blood Pressure / drug effects
  • Female
  • Fluid Therapy / methods*
  • Heart Rate / drug effects
  • Hepatectomy / adverse effects*
  • Humans
  • Hydroxyethyl Starch Derivatives / administration & dosage
  • Hypotension / diagnosis
  • Hypotension / etiology
  • Hypotension / prevention & control*
  • Infusions, Intravenous
  • Intraoperative Complications / diagnosis
  • Intraoperative Complications / etiology
  • Intraoperative Complications / prevention & control*
  • Liver / blood supply
  • Liver / drug effects
  • Liver / surgery
  • Liver Neoplasms / surgery
  • Male
  • Monitoring, Intraoperative / methods
  • Norepinephrine / administration & dosage
  • Phenylephrine / administration & dosage
  • Stroke Volume / drug effects
  • Treatment Outcome
  • Vasoconstrictor Agents / administration & dosage*

Substances

  • Hydroxyethyl Starch Derivatives
  • Vasoconstrictor Agents
  • Phenylephrine
  • Norepinephrine