Objectives: To identify patient-reported experience measures (PREMs), assess their validity and reliability, and assess any bias in the study design of PREM validity and reliability testing.
Data sources/study setting: Articles reporting on PREM development and testing sourced from MEDLINE, CINAHL and Scopus databases up to March 13, 2018.
Study design: Systematic review.
Data collection/extraction methods: Critical appraisal of PREM study design was undertaken using the Appraisal tool for Cross-Sectional Studies (AXIS). Critical appraisal of PREM validity and reliability was undertaken using a revised version of the COSMIN checklist.
Principal findings: Eighty-eight PREMs were identified, spanning across four main health care contexts. PREM validity and reliability was supported by appropriate study designs. Internal consistency (n = 58, 65.2 percent), structural validity (n = 49, 55.1 percent), and content validity (n = 34, 38.2 percent) were the most frequently reported validity and reliability tests.
Conclusions: Careful consideration should be given when selecting PREMs, particularly as seven of the 10 validity and reliability criteria were not undertaken in ≥50 percent of the PREMs. Testing PREM responsiveness should be prioritized for the application of PREMs where the end user is measuring change over time. Assessing measurement error/agreement of PREMs is important to understand the clinical relevancy of PREM scores used in a health care evaluation capacity.
Keywords: health care organization and systems; reliability; survey research and questionnaire design; systematic reviews/meta-analyses; validity.
© Health Research and Educational Trust.