Site-resolved imaging of beryllium ion crystals in a high-optical-access Penning trap with inbore optomechanics

Rev Sci Instrum. 2019 May;90(5):053103. doi: 10.1063/1.5049506.

Abstract

We present the design, construction, and characterization of an experimental system capable of supporting a broad class of quantum simulation experiments with hundreds of spin qubits using 9Be+ ions in a Penning trap. This article provides a detailed overview of the core optical and trapping subsystems and their integration. We begin with a description of a dual-trap design separating loading and experimental zones and associated vacuum infrastructure design. The experimental-zone trap electrodes are designed for wide-angle optical access (e.g., for lasers used to engineer spin-motional coupling across large ion crystals) while simultaneously providing a harmonic trapping potential. We describe a near-zero-loss liquid-cryogen-based superconducting magnet, employed in both trapping and establishing a quantization field for ion spin-states and equipped with a dual-stage remote-motor LN2/LHe recondenser. Experimental measurements using a nuclear magnetic resonance (NMR) probe demonstrate part-per-million homogeneity over 7 mm-diameter cylindrical volume, with no discernible effect on the measured NMR linewidth from pulse-tube operation. Next, we describe a custom-engineered inbore optomechanical system which delivers ultraviolet (UV) laser light to the trap and supports multiple aligned optical objectives for topview and sideview imaging in the experimental trap region. We describe design choices including the use of nonmagnetic goniometers and translation stages for precision alignment. Furthermore, the optomechanical system integrates UV-compatible fiber optics which decouple the system's alignment from remote light sources. Using this system, we present site-resolved images of ion crystals and demonstrate the ability to realize both planar and three-dimensional ion arrays via control of rotating wall electrodes and radial laser beams. Looking to future work, we include interferometric vibration measurements demonstrating root-mean-square trap motion of ∼33 nm (∼117 nm) in the axial (transverse) direction; both values can be reduced when operating the magnet in free-running mode. The paper concludes with an outlook toward extensions of the experimental setup, areas for improvement, and future experimental studies.