Cefazolin-gentamicin versus taurolidine-citrate for the prevention of infection in tunneled central catheters in hemodialysis patients: A quasi-experimental trial

Int J Infect Dis. 2019 Aug:85:16-21. doi: 10.1016/j.ijid.2019.05.017. Epub 2019 May 15.

Abstract

Background: Catheter-related bloodstream infection (CR-BSI) is one of various complications related to hemodialysis (HD). As a result of the high rate of infection, the use of lock solutions for the prevention of CR-BSI has been studied. However, adverse effects of lock solution, such as increased emergence of strains resistant to antibiotics, which is an important concern, need to be investigated further. The aim of this study was to compare the efficacy of lock solution using a combination of cefazolin and gentamicin versus taurolidine and citrate in reducing CR-BSI in patients undergoing HD and to identify any adverse effects.

Methods: A prospective observational study was performed at two dialysis centers. Patients using new tunneled central venous catheters (CVC) for HD were included. Patients with a tunneled CVC were assigned to receive either antibiotic lock solution (group 1: gentamicin 7mg/ml+cefazolin 12mg/ml+heparin 3500IU/ml) or lock solution with TauroLock-Hep500 (group 2: taurolidine citrate 4%+heparin 500 IU/ml) during the inter-dialysis period. The patients were allocated to these groups according to the hemodialysis center they were attending.

Results: A total of 145 CVCs were implanted in 127 patients and were followed for 15 months: 77 CVCs (65 patients) were placed in group 1 and 68 CVCs (62 patients) in group 2. There was no difference between the two groups with regard to CR-BSI (events per 1000 catheter-days: group 1=0.79, group 2=1.10; p=0.18) or exit site infection rates (events per 1000 catheter-days: group 1=2.45, group 2=1.83; p=0.37). The groups differed in ESI pathogens, with gram-positive oxacillin-resistant pathogens more frequent in group 1 (31.8% vs. 5.0%; p=0.003). The two groups were similar in mechanical complications. In the Cox regression analysis, the internal jugular vein site was a protective factor for all catheter removal complications (hazard ratio (HR) 0.41, 95% confidence interval (CI) 0.19-0.91) and mechanical complications (HR 0.16, 95% CI 0.065-0.41); only ESI was a risk factor for all catheter removal complications (HR 1.79, 95% CI 1.04-3.07) and mechanical complications (HR 5.64, 95% CI 1.65-19.3).

Conclusions: The efficacy of both lock solutions was similar in preventing infections related to tunneled CVCs for HD. However, there were more oxacillin-resistant strains in patients who received antibiotic lock solution. Further studies are required to determine the optimal drug regimen and concentrations for lock solution and the associated adverse effects.

Keywords: Catheter-related bloodstream infection; Hemodialysis; Lock therapy; Tunneled catheter.

Publication types

  • Clinical Trial
  • Comparative Study

MeSH terms

  • Adult
  • Aged
  • Anti-Bacterial Agents / therapeutic use*
  • Catheter-Related Infections / etiology
  • Catheter-Related Infections / prevention & control*
  • Cefazolin / therapeutic use*
  • Central Venous Catheters
  • Citric Acid / therapeutic use*
  • Device Removal
  • Female
  • Gentamicins / therapeutic use
  • Humans
  • Male
  • Middle Aged
  • Proportional Hazards Models
  • Prospective Studies
  • Renal Dialysis / adverse effects*
  • Risk Factors
  • Taurine / analogs & derivatives*
  • Taurine / therapeutic use
  • Thiadiazines / therapeutic use*

Substances

  • Anti-Bacterial Agents
  • Gentamicins
  • Thiadiazines
  • Taurine
  • Citric Acid
  • taurolidine
  • Cefazolin