Impact of Renal Artery Stent-Graft Placement on Renal Function in Chronic Aortic Dissection

J Vasc Interv Radiol. 2019 Jul;30(7):979-986. doi: 10.1016/j.jvir.2018.12.015. Epub 2019 Apr 11.

Abstract

Purpose: To evaluate the effect of renal stent-graft placement on kidney function and size alternation in chronic aortic dissection.

Materials and methods: Twenty-five consecutive patients with chronic aortic dissection after thoracic endovascular aortic repair who underwent renal stent-graft placement between January 2015 and December 2016 were retrospectively reviewed. Forty-three patients with chronic aortic dissection who received thoracic endovascular aortic repair in the same period were reviewed as a control group for kidney volume comparison.

Results: Twenty-five stent-grafts were deployed over 25 renal arteries. Overall renal function was assessed by the slope of the regression line constructed from the plots of creatinine clearance versus time within 2 years after the procedure (-0.2810 vs -0.3146 mL/min-1/mo-1, P = .868), kidney volume at 12 months (129.4 ± 40.9 vs 137.0 ± 44.2 cm2, P = .193) and effective renal plasma flow at 6 months (106.3 ± 46.9 vs 124.4 ± 55.5 mL/min, P = .050) and was not significantly deteriorated. Seven treated patients (87.5%) with a renal artery supplied by a false lumen had a decrease in kidney volume, as did 14 patients (56%) in the control group (P = .206). Three patients with a dissected renal artery (75%) in the stent-graft group had an increase in kidney volume compared with 1 patient (11.1%) in the control group (P = .052).

Conclusions: Occlusion of the re-entry tear by a stent-graft in the renal artery remains a safe strategy to promote false lumen thrombosis. The stent-graft poses a potential risk of reducing the kidney volume in kidneys supplied by the false lumen but may provide a positive effect in kidney volume with a concomitant dissected renal artery in chronic aortic dissection.

MeSH terms

  • Adult
  • Aged
  • Aortic Aneurysm / diagnostic imaging
  • Aortic Aneurysm / physiopathology
  • Aortic Aneurysm / surgery*
  • Aortic Dissection / diagnostic imaging
  • Aortic Dissection / physiopathology
  • Aortic Dissection / surgery*
  • Blood Vessel Prosthesis Implantation / adverse effects
  • Blood Vessel Prosthesis Implantation / instrumentation*
  • Blood Vessel Prosthesis*
  • Chronic Disease
  • Endovascular Procedures / adverse effects
  • Endovascular Procedures / instrumentation*
  • Female
  • Humans
  • Kidney / blood supply*
  • Kidney / physiopathology
  • Male
  • Middle Aged
  • Postoperative Complications / etiology
  • Renal Artery / diagnostic imaging
  • Renal Artery / physiopathology
  • Renal Artery / surgery*
  • Retrospective Studies
  • Risk Factors
  • Stents*
  • Time Factors
  • Treatment Outcome