Objective and subjective comparison of virtual monoenergetic vs. polychromatic images in patients with pancreatic ductal adenocarcinoma

Eur Radiol. 2019 Jul;29(7):3617-3625. doi: 10.1007/s00330-019-06116-9. Epub 2019 Mar 19.

Abstract

Objectives: The aim of this study was to assess the objective and subjective image characteristics of monoenergetic images (MEI[+]), using a noise-optimized algorithm at different kiloelectron volts (keV) compared to polyenergetic images (PEI), in patients with pancreatic ductal adenocarcinoma (PDAC).

Methods: This retrospective, institutional review board-approved study included 45 patients (18 male, 27 female; mean age 66 years; range, 42-96 years) with PDAC who had undergone a dual-energy CT (DECT) of the abdomen for staging. One standard polyenergetic image (PEI) and five MEI(+) images in 10-keV intervals, ranging from 40 to 80 keV, were reconstructed. Line-density profile analysis, as well as the contrast-to-noise ratio (CNR) of the tumor, the signal-to-noise ratio (SNR) of the regular pancreas parenchyma and the tumor, and the CNR of the three main peripancreatic vessels, was calculated. For subjective quality assessment, two readers independently assessed the images using a 5-point Likert scale. Reader reliability was evaluated using an intraclass correlation coefficient.

Results: Line-density profile analysis revealed the largest gradient in attenuation between PDAC and regular tissue in MEI(+) at 40 keV. Low-keV MEI(+)reconstructions at 40 and 50 keV increased CNR and SNR compared to PEI (40 keV: CNR 46.8 vs. 7.5; SNRPankreas 32.5 vs. 15.7; SNRLesion 13.5 vs. 8.6; p < 0.001). MEI(+) at 40 keV and 50 keV were consistently preferred by the observers (p < 0.05), showing a high intra-observer 0.937 (0.92-0.95) and inter-observer 0.911 (0.89-0.93) agreement.

Conclusion: MEI(+) reconstructions at 40 keV and 50 keV provide better objective and subjective image quality compared to conventional PEI of DECT in patients with PDAC.

Key points: • Low-keV MEI(+) reconstructions at 40 and 50 keV increase tumor-to-pancreas contrast compared to PEI. • Low-keV MEI(+) reconstructions improve objective and subjective image quality parameters compared to PEI. • Dual-energy post-processing might be a valuable tool in the diagnostic workup of patients with PDAC.

Keywords: Multidetector computed tomography; Pancreatic neoplasms; Signal-to-noise ratio.

Publication types

  • Comparative Study

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Algorithms*
  • Carcinoma, Pancreatic Ductal / diagnosis*
  • Female
  • Humans
  • Image Processing, Computer-Assisted / methods*
  • Male
  • Middle Aged
  • Pancreas / diagnostic imaging*
  • Pancreatic Neoplasms / diagnosis*
  • Radiography, Dual-Energy Scanned Projection / methods*
  • Reproducibility of Results
  • Retrospective Studies
  • Virtual Reality*