Objective: The neonate premaxilla in bilateral cleft lip and palate is often protruding and displaced laterally. Surgeons prefer the premaxilla to be repositioned and centralized to allow a tension-free primary lip repair. This report describes the fabrication of a premaxillary bonnet appliance with silicone material and its successful use in 2 cases of bilateral cleft lip and palate (BCLP).
Patients, participants: Two male BCLP patients of ages 34 days and 10 days, respectively.
Interventions: Nonsurgical repositioning of the premaxillary segment using silicone cup-bonnet appliance.
Results: The duration of active treatment by silicone appliance was 36 days in case 1 and 75 days in case 2. The retention period was 2 months and 3 months, respectively. The appliance made of room temperature vulcanizing (RTV) silicone is flexible and softer in comparison to the rigid conventional acrylic appliance and is therefore almost atraumatic. A gentler appliance resulted in enhanced compliance and acceptance by the neonates. There was a noticeable change in the position of the discernible asymmetric premaxilla. Analysis of frontal facial photographs revealed an angular change in the position of the premaxilla (C) by 12° in case 1 and 6° in case 2 in reference to the midfacial plane.
Conclusion: This silicone appliance provides enhanced compliance and improved retention compared to acrylic appliance since it is a more gentle, flexible, and less traumatic alternative to a rigid acrylic appliance. Further, the RTV silicone appliance can be 3-dimensionally printed for better accuracy following intraoral scanning and thus eliminating the need for impression making in cleft newborns.
Keywords: infant orthopedics; maxilla; nonsyndromic clefting; orthodontics.