Production of RBC autoantibody mimicking anti-D specificity following transfusion in a patient with weak D Type 15

Transfusion. 2019 Apr;59(4):1190-1195. doi: 10.1111/trf.15207. Epub 2019 Feb 19.

Abstract

Background: Weak D-type RBCs have fewer D epitopes, but it remains unclear whether individuals with certain types of weak D produce alloanti-D directed at D epitopes absent from the RBCs, and whether it is an alloantibody or an autoantibody. We report the first case of a patient with a weak D Type 15 who produced autoantibodies mimicking alloanti-D.

Case report: A 52-year-old Japanese male with weak D developed anti-D 3 months after transfusion of D-negative and -positive RBCs, and the antibody persisted for 24 months with a consistently negative direct antiglobulin test. Eluates from the patient's RBCs demonstrated anti-D specificity. The recipient did not exhibit any signs of delayed hemolytic transfusion reaction. As his anti-D was removed by the different adsorbing cells of weak D Type 15 and autologous as well as D positive, D negative, weak D Type 24, and partial DVa, it was thought to be an autoantibody mimicking anti-D rather than an alloantibody. The patient's RBCs reacted weakly with the 13 anti-D reagents used in the study. Polymerase chain reaction and nucleotide sequencing revealed that the patient had an RHD genotype of RHD*01N.01/RHD*15.

Conclusion: Anti-D, produced in a patient with weak D Type 15 after transfusion, was found to be mimicking autoanti-D. Alloanti-D was excluded by an adsorption study with different RBC types.

Publication types

  • Case Reports

MeSH terms

  • Blood Transfusion*
  • Erythrocytes / metabolism*
  • Humans
  • Isoantibodies / blood*
  • Male
  • Middle Aged
  • Rho(D) Immune Globulin / blood*
  • Transfusion Reaction / blood*

Substances

  • Isoantibodies
  • RHO(D) antibody
  • Rho(D) Immune Globulin