Analyzing the post-contrast attenuation of the esophageal wall on routine contrast-enhanced MDCT examination can improve the diagnostic accuracy in response evaluation of the squamous cell esophageal carcinoma to neoadjuvant chemoradiotherapy in comparison with the esophageal wall thickness

Abdom Radiol (NY). 2019 May;44(5):1722-1733. doi: 10.1007/s00261-019-01911-w.

Abstract

Purpose: To evaluate the accuracy of the multidetector computed tomography (MDCT) in the response evaluation of the esophageal squamous cell carcinoma (ESCC) to neoadjuvant chemoradiotherapy (nCRT) by analyzing the thickness and post-contrast attenuation of the esophageal wall after the nCRT.

Methods: Contrast-enhanced (CE)-MDCT examinations in portal venous phase of one hundred patients with locally advanced ESCC who received nCRT and underwent esophageal resection and histopathology assessment of tumor regression grade (TRG) were retrospectively analyzed by measuring the maximal thickness and mean density of the esophageal wall in the segment involved by tumor and visually searching for hyperdense foci within it. Diagnostic performance was evaluated using the ROC analysis.

Results: Average attenuation of the esophageal wall had stronger diagnostic performance for predicting pathologic complete regression (pCR) (AUC = 0.994; p < 0.001) in relation to maximal esophageal wall thickness (AUC = 0.731; p < 0.001). Maximal esophageal wall thickness ≤ 9 mm and average attenuation of the esophageal wall ≤ 64 HU predicted pCR with the sensitivity, specificity, and overall accuracy of 62.5%, 77.9%, and 73%, and 96.9%, 98.5%, and 98%, respectively. Combination of both cutoff values enabled correct assessment of pCR with the 100% accuracy. Visual detection of the hyperdense focus within the esophageal wall predicted pCR with the sensitivity, specificity, and overall accuracy values of 100%, 94.1%, and 96%, respectively.

Conclusion: Visual analysis and measurement of post-contrast attenuation of the esophageal wall after the nCRT can improve diagnostic accuracy of MDCT in the response evaluation of the ESCC to nCRT in comparison with measuring the esophageal wall thickness.

Keywords: Esophageal neoplasms; Multidetector computed tomography; Neoadjuvant therapy; Treatment outcome.

Publication types

  • Comparative Study

MeSH terms

  • Aged
  • Carcinoma, Squamous Cell / diagnostic imaging*
  • Carcinoma, Squamous Cell / pathology
  • Carcinoma, Squamous Cell / therapy
  • Chemoradiotherapy
  • Contrast Media
  • Esophageal Neoplasms / diagnostic imaging*
  • Esophageal Neoplasms / pathology
  • Esophageal Neoplasms / therapy
  • Esophagus / diagnostic imaging
  • Esophagus / pathology
  • Female
  • Humans
  • Male
  • Middle Aged
  • Multidetector Computed Tomography*
  • Neoadjuvant Therapy
  • Retrospective Studies
  • Sensitivity and Specificity

Substances

  • Contrast Media