Risk of death without appropriate defibrillator shock in patients with advanced renal dysfunction

Europace. 2019 Mar 1;21(3):459-464. doi: 10.1093/europace/euy305.

Abstract

Aims: Heart failure patients with advanced chronic kidney disease (CKD) may experience an increased rate of non-arrhythmic mortality due to associated comorbidities. We aimed to evaluate the risk of mortality without appropriate implantable cardioverter-defibrillator (ICD) shocks in this high-risk population.

Methods and results: The study population comprised 3542 patients who received an ICD, were enrolled, and prospectively followed-up in the Israeli ICD registry. Study patients were categorized into two groups: those with advanced CKD [defined by a glomerular filtration rate of <30 mL/min/1.73 m2 or being on dialysis at time of implantation (n = 197)], and those without advanced CKD (n = 3344). The primary endpoint was the risk of death without receiving appropriate ICD shock. Kaplan-Meier survival analysis showed that at 5 years of follow-up the rates of death without prior ICD shock were significantly higher in the advanced kidney disease group (46%) compared with the non-advanced CKD group (19%; log-rank P-value <0.001). Consistently, multivariate analysis showed that the risk of death without receiving appropriate ICD shock therapy at 5 years was 2.5-fold (P < 0.001) higher among advanced CKD patients. In contrast, the rate of appropriate ICD shock therapy at 5 years among advanced CKD patients was only 9%, with a very high mortality rate (63%) within 3.5 years subsequent to shock therapy.

Conclusion: Nearly one-half of ICD with advanced CKD die within 5 years without receiving an appropriate ICD shock. These findings stress the importance of appropriate patient selection for primary ICD implantation in this high-risk population.

Keywords: Appropriate shock; Chronic kidney disease; Implantable cardioverter-defibrillator.

MeSH terms

  • Aged
  • Clinical Decision-Making
  • Death, Sudden, Cardiac / prevention & control*
  • Defibrillators, Implantable*
  • Electric Countershock / adverse effects
  • Electric Countershock / instrumentation*
  • Electric Countershock / mortality
  • Female
  • Glomerular Filtration Rate*
  • Heart Failure / diagnosis
  • Heart Failure / mortality*
  • Heart Failure / physiopathology
  • Heart Failure / therapy*
  • Humans
  • Israel
  • Kidney / physiopathology*
  • Male
  • Middle Aged
  • Prospective Studies
  • Registries
  • Renal Dialysis
  • Renal Insufficiency, Chronic / diagnosis
  • Renal Insufficiency, Chronic / mortality*
  • Renal Insufficiency, Chronic / physiopathology
  • Renal Insufficiency, Chronic / therapy
  • Risk Assessment
  • Risk Factors
  • Time Factors
  • Treatment Outcome