Surgical aortic valve replacement and patient-prosthesis mismatch: a meta-analysis of 108 182 patients

Eur J Cardiothorac Surg. 2019 Jul 1;56(1):44-54. doi: 10.1093/ejcts/ezy466.

Abstract

Objectives: This study sought to evaluate the impact of patient-prosthesis mismatch (PPM) on the risk of perioperative, early-, mid- and long-term mortality rates after surgical aortic valve replacement.

Methods: Databases were searched for studies published until March 2018. The main outcomes of interest were perioperative mortality, 1-year mortality, 5-year mortality and 10-year mortality.

Results: The search yielded 3761 studies for inclusion. Of these, 70 articles were analysed, and their data were extracted. The total number of patients included was 108 182 who underwent surgical aortic valve replacement. The incidence of PPM after surgical aortic valve replacement was 53.7% (58 116 with PPM and 50 066 without PPM). Perioperative mortality [odds ratio (OR) 1.491, 95% confidence interval (CI) 1.302-1.707; P < 0.001], 1-year mortality (OR 1.465, 95% CI 1.277-1.681; P < 0.001), 5-year mortality (OR 1.358, 95% CI 1.218-1.515; P < 0.001) and 10-year mortality (OR 1.534, 95% CI 1.290-1.825; P < 0.001) were increased in patients with PPM. Both severe PPM and moderate PPM were associated with increased risk of perioperative mortality, 1-year mortality, 5-year mortality and 10-year mortality when analysed together and separately, although we observed a higher risk in the group with severe PPM.

Conclusions: Moderate/severe PPM increases perioperative, early-, mid- and long-term mortality rates proportionally to its severity. The findings of this study support the implementation of surgical strategies to prevent PPM in order to decrease mortality rates.

Keywords: Aortic stenosis; Aortic valve replacement; Heart valve prosthesis; Meta-analysis; Prosthesis–patient mismatch.

Publication types

  • Meta-Analysis

MeSH terms

  • Aortic Valve / surgery*
  • Aortic Valve Stenosis / surgery
  • Heart Valve Prosthesis / adverse effects*
  • Heart Valve Prosthesis Implantation* / adverse effects
  • Heart Valve Prosthesis Implantation* / mortality
  • Humans
  • Prosthesis Failure*