The n-HA/PA66 Cage Versus the PEEK Cage in Anterior Cervical Fusion with Single-Level Discectomy During 7 Years of Follow-Up

World Neurosurg. 2019 Mar:123:e678-e684. doi: 10.1016/j.wneu.2018.11.251. Epub 2018 Dec 18.

Abstract

Objective: The nano-hydroxyapatite/polyamide66 (n-HA/PA66) cage is a novel biomimetic nonmetal cage, whereas the polyetheretherketone (PEEK) cage has been widely used for decades with excellent clinical outcomes. However, there has been no long-term comparison of these 2 cages in anterior cervical reconstruction.

Methods: This retrospective study included 98 patients who underwent single-level anterior cervical decompression and fusion (ACDF) from January 2009 to June 2011 with at least 7 years of follow-up; the PEEK cage was used in 51 patients (PEEK group), whereas the n-HA/PA66 cage was used in 47 (n-HA/PA66 group). The groups were compared regarding radiographic (cage subsidence, fusion status, cervical lordosis, and segmental sagittal alignment) and clinical (10-point visual analog scale and Japanese Orthopedic Association scores) parameters preoperatively, postoperatively, and at the final follow-up.

Results: The n-HA/PA66 and PEEK cages had similar fusion rates at the final follow-up (97.9% vs. 98.0%). The respective cage subsidence rates in the PEEK and n-HA/PA66 cage groups were 9.8% and 10.6%. There were no significant differences between the 2 groups in mean cervical lordosis, mean interbody height, segmental sagittal alignment, cervical lordosis, and 10-point visual analog scale and Japanese Orthopedic Association scores at the final follow-up. The n-HA/PA66 cages resulted in high fusion and low subsidence rates during long-term follow-up.

Conclusions: After single-level ACDF, the n-HA/PA66 cage showed similar radiographic fusion, subsidence rate, and clinical results compared with the PEEK cage during 7 years of follow-up. These results suggest that the n-HA/PA66 cage could be comparable with the PEEK cage for ACDF.

Keywords: Cage; Cervical spine; Discectomy; Fusion; Nano-hydroxyapatite/polyamide66 cage; Polyetheretherketone cage.

Publication types

  • Comparative Study

MeSH terms

  • Adult
  • Aged
  • Benzophenones
  • Cervical Vertebrae / diagnostic imaging
  • Cervical Vertebrae / surgery*
  • Diskectomy / instrumentation*
  • Durapatite
  • Female
  • Follow-Up Studies
  • Humans
  • Internal Fixators*
  • Ketones
  • Male
  • Middle Aged
  • Plastic Surgery Procedures / instrumentation
  • Polyethylene Glycols
  • Polymers
  • Retrospective Studies
  • Spinal Fusion / instrumentation*
  • Time Factors
  • Treatment Outcome

Substances

  • Benzophenones
  • Ketones
  • Polymers
  • polyetheretherketone
  • Polyethylene Glycols
  • Durapatite