Noise exposure and hearing status among call center operators

Noise Health. 2018 Sep-Oct;20(96):178-189. doi: 10.4103/nah.NAH_11_18.

Abstract

Introduction: The overall objective of the study was to assess noise exposure and audiometric hearing threshold levels (HTLs) in call center operators.

Materials and methods: Standard pure-tone audiometry and extended high-frequency audiometry were performed in 78 participants, aged 19 to 44 years (mean ± standard deviation: 28.1 ± 6.3 years), employed up to 12 years (2.7 ± 2.9 years) at one call center. All participants were also inquired about their communication headset usage habits, hearing-related symptoms, and risk factors for noise-induced hearing loss (NIHL). Noise exposure under headsets was evaluated using the microphone in a real ear technique as specified by ISO 11904-1:2002. The background noise prevailing in offices was also measured according to ISO 9612:2009.

Results and discussion: A personal daily noise exposure level calculated by combining headset and nonheadset work activities ranged from 68 to 79 dBA (74.7 ± 2.5 dBA). Majority (92.3%) of study participants had normal hearing in both ears (mean HTL in the frequency range of 0.25-8 kHz ≤20 dB HL). However, their HTLs in the frequency range of 0.25 to 8 kHz were worse than the expected median values for equivalent highly screened otologically normal population, whereas above 8 kHz were comparable (9-11.2 kHz) or better (12.5 kHz). High-frequency hearing loss (mean HTLs at 3, 4, and 6 kHz >20 dB HL) and speech-frequency hearing loss (mean HTLs at 0.5, 1, 2, and 4 kHz >20 dB HL) were noted in 8.3% and 6.4% of ears, respectively. High-frequency notches were found in 15.4% of analyzed audiograms. Moreover, some of call center operators reported hearing-related symptoms.

Conclusions: Further studies are needed before firm conclusions concerning the risk of NIHL in this professional group can be drawn.

Keywords: call center; communication headset; hearing loss; noise exposure.

MeSH terms

  • Adult
  • Audiometry, Pure-Tone
  • Call Centers*
  • Female
  • Hearing Loss, High-Frequency / epidemiology*
  • Hearing Loss, High-Frequency / etiology
  • Hearing Loss, Noise-Induced / epidemiology*
  • Hearing Loss, Noise-Induced / etiology
  • Humans
  • Male
  • Noise, Occupational / adverse effects*
  • Occupational Diseases / epidemiology*
  • Occupational Diseases / etiology
  • Risk Factors
  • Young Adult