Significance of the intraindividual variability of HLA IgG antibodies in renal disease patients observed with different beadsets monitored with two different secondary antibodies on a Luminex platform

Immunol Res. 2018 Oct;66(5):584-604. doi: 10.1007/s12026-018-9027-2.

Abstract

The accurate measurement of anti-HLA alloantibodies in transplant candidates is required for determining the degree of sensitization and for the listing of unacceptable antigens for organ allocation. Both the configuration of the HLA molecules coated on the beads and the nature of detection antibodies may impede assessment of the presence and strength of anti-HLA IgG- with the Luminex single-antigen-bead assay. Sera antibodies of the end-stage renal disease patients were compared using LIFECODES (LC) and LABScreen (LS) beadsets monitored with polyclonal-Fab (IgHPolyFab) and monoclonal-IgG (FcMonoIgG) second antibodies. Positive results at mean fluorescence intensity (MFI) > 500 (at serum dilution 1/10) were used to calculate panel reactive antibody (cPRA) levels. LS-beadsets are coated with monomeric variants in addition to intact HLA antigens with or without peptides, while LC-beadsets are devoid of monomeric variants and with lesser levels of peptide-free heterodimers. Consequently, IgG antibodies against both classes of HLA were reactive to more antigens with LS than with LC-beadsets. For both classes, MFIs were also frequently higher with LS than with LC. For HLA-I, MFIs were higher with IgHPolyFab than with FcMonoIgG with the exception of sera with MFIs > 5000 where they were comparable. For HLA-II, the reverse occurred, with significantly higher levels with FcMonoIgG regardless of the beadsets. The intraindividual variability observed between beadsets with two detection antibodies elucidates that antigens found as acceptable with one beadset may end up unacceptable with the other beadsets, with the possibility of denying potentially compatible transplants to candidates.

Keywords: Calculated panel reactive antibody (cPRA); Denatured antigen; FcMonoIgG; Heavy chain; Human leukocyte antigen; IgHPolyFab: MFI: mean fluorescent intensity (MFI); Single antigen bead assays (SAB); β2-microglobulin.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Antibodies / blood*
  • Epitope Mapping
  • HLA Antigens / immunology*
  • Histocompatibility
  • Humans
  • Immunoglobulin G / blood*
  • Isoantibodies / blood*
  • Kidney Transplantation*
  • Observer Variation
  • Renal Insufficiency, Chronic / diagnosis*
  • Renal Insufficiency, Chronic / immunology

Substances

  • Antibodies
  • HLA Antigens
  • Immunoglobulin G
  • Isoantibodies