Device-Related Thrombus After Left Atrial Appendage Occlusion With the Amulet Device

Heart Lung Circ. 2019 Nov;28(11):1683-1688. doi: 10.1016/j.hlc.2018.08.022. Epub 2018 Sep 27.

Abstract

Background: Left atrial appendage occlusion (LAAO) is increasingly used for stroke prevention in patients with atrial fibrillation who are considered unsuitable for a lifelong oral anticoagulant regimen. Recently, a single-centre study reported device-related thrombus formation in 16.7% of patients treated with the second-generation Amulet device (St. Jude Medical, St. Paul, MN, USA), presenting a potential major safety concern. As "real-world" data on device-related thrombus formation following LAAO with the Amulet occluder are scarce, we aimed to evaluate this outcome in a retrospective registry.

Methods: Clinical and tranosesophageal echocardiography data after LAAO with the Amulet in consecutive patients from three centres were collated.

Results: Among 38 patients (mean age 75.8 years), mean (standard deviation) CHA2DS2-VASc and HAS-BLED scores were 4.4 (1.2) and 3.4 (0.9), respectively. All patients underwent successful device placement without procedure-related adverse events. The antithrombotic regimen at discharge consisted of dual antiplatelet therapy (DAPT) in 27 patients (71.1%), single antiplatelet therapy in 10 patients (26.3%), and no antithrombotic therapy in one patient (2.6%). Device-related thrombus was observed in one patient (2.6%) despite DAPT regimen. The outcome of this patient was uncomplicated after adjustment of oral anticoagulant therapy. No patients presented with a thromboembolic event following LAAO during a mean (standard deviation) follow-up of 15 (5) months.

Conclusions: In this retrospective study, device-related thrombus formation with the second-generation Amulet device was rare and occurred at a rate similar to that of the previous device. Importantly, no patient experienced a device-related thromboembolic event during follow-up. Larger real-life studies are required to confirm the safety profile of this increasingly used device.

Keywords: Atrial fibrillation; Device-related thrombus formation; Left atrial appendage occlusion; Stroke prevention.

Publication types

  • Multicenter Study

MeSH terms

  • Administration, Oral
  • Aged
  • Aged, 80 and over
  • Anticoagulants / administration & dosage
  • Atrial Fibrillation / complications
  • Atrial Fibrillation / therapy
  • Echocardiography, Transesophageal
  • Female
  • Follow-Up Studies
  • Heart Atria*
  • Heart Diseases / diagnosis
  • Heart Diseases / etiology*
  • Humans
  • Male
  • Middle Aged
  • Postoperative Complications / diagnosis
  • Postoperative Complications / etiology*
  • Retrospective Studies
  • Septal Occluder Device / adverse effects*
  • Stroke / prevention & control*
  • Thrombosis / diagnosis
  • Thrombosis / etiology*

Substances

  • Anticoagulants