Cumulative Radiation Exposures from CT Screening and Surveillance Strategies for von Hippel-Lindau-associated Solid Pancreatic Tumors

Radiology. 2019 Jan;290(1):116-124. doi: 10.1148/radiol.2018180687. Epub 2018 Oct 9.

Abstract

Purpose To assess the potential ionizing radiation exposure from CT scans for both screening and surveillance of patients with von Hippel-Lindau (VHL) syndrome. Materials and Methods For this retrospective study, abdomen-pelvic (AP) and chest-abdomen-pelvic (CAP) CT scans were performed with either a three-phase (n = 1242) or a dual-energy virtual noncontrast protocol (VNC; n = 149) in 747 patients with VHL syndrome in the National Institutes of Health Clinical Center between 2009 and 2015 (mean age, 47.6 years ± 14.6 [standard deviation]; age range, 12-83 years; 320 women [42.8%]). CT scanning parameters for patients with pancreatic neuroendocrine tumors (PNETs; 124 patients and 381 scans) were compared between a tumor diameter-based surveillance protocol and a VHL genotype and tumor diameter-based algorithm (a tailored algorithm) developed by three VHL clinicians. Organ and lifetime radiation doses were estimated by two radiologists and five radiation scientists. Cumulative radiation doses were compared between the PNET surveillance algorithms by analyses of variance, and a two-tailed P value less than .05 indicated statistical significance. Results Median cumulative colon doses for annual CAP and AP CT scans from age 15 to 40 years ranged from 0.34 Gy (5th-95th percentiles, 0.18-0.75; dual-energy VNC CT) to 0.89 Gy (5th-95th percentiles, 0.42-1.0; three-phase CT). For the current PNET surveillance protocol, the cumulative effective radiation dose from age 40 to 65 years was 682 mSv (tumors < 1.2 cm) and 2125 mSv (tumors > 3 cm). The tailored algorithm could halve these doses for patients with initial tumor diameter less than 1.2 cm (P < .001). Conclusion CT screening of patients with von Hippel-Lindau syndrome can lead to substantial radiation exposures, even with dual-energy virtual noncontrast CT. A genome and tumor diameter-based algorithm for pancreatic neuroendocrine tumor surveillance may potentially reduce lifetime radiation exposure. © RSNA, 2018 Online supplemental material is available for this article.

Publication types

  • Research Support, N.I.H., Intramural

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Child
  • Female
  • Humans
  • Male
  • Middle Aged
  • Pancreatic Neoplasms* / diagnostic imaging
  • Pancreatic Neoplasms* / etiology
  • Radiation Exposure* / analysis
  • Radiation Exposure* / statistics & numerical data
  • Retrospective Studies
  • Tomography, X-Ray Computed*
  • Young Adult
  • von Hippel-Lindau Disease* / complications
  • von Hippel-Lindau Disease* / diagnostic imaging