Improved glycemic control with minimal systemic metformin exposure: Effects of Metformin Delayed-Release (Metformin DR) targeting the lower bowel over 16 weeks in a randomized trial in subjects with type 2 diabetes

PLoS One. 2018 Sep 25;13(9):e0203946. doi: 10.1371/journal.pone.0203946. eCollection 2018.

Abstract

Objective: Metformin use is restricted in patients with renal impairment due to potential excess systemic accumulation. This study evaluated the glycemic effects and safety of metformin delayed-release (Metformin DR), which targets metformin delivery to the ileum to leverage its gut-based mechanisms of action while minimizing systemic exposure.

Research designs and methods: Participants (T2DM [HbA1c 7-10.5%], eGFR ≥60 mL/min/1.73m2, not taking metformin for ≥2 months) were randomized to QD placebo (PBO); QD Metformin DR 600, 900, 1200, or 1500 mg; or to single-blind BID Metformin immediate-release (IR) 1000 mg. The primary endpoint was change in HbA1c for Metformin DR vs. PBO at 16 weeks in the modified intent-to-treat (mITT) population (≥ 1 post-baseline HbA1c while on study drug), using a mixed-effects repeated measures model.

Results: 571 subjects were randomized (56 years, 53% male, 80% white; BMI 32.2±5.5 kg/m2; HbA1c 8.6±0.9%; 51% metformin naive); 542 were in the mITT population. Metformin DR 1200 and 1500 mg significantly reduced HbA1c (-0.49±0.13% and -0.62±0.12%, respectively, vs. PBO -0.06±0.13%; p<0.05) and FPG (Caverage Weeks 4-16: -22.3±4.2 mg/dL and -25.1±4.1 mg/dL, respectively vs. -2.5±4.2 mg/dL p<0.05). Metformin IR elicited greater HbA1c improvement (-1.10±0.13%; p<0.01 vs. Placebo and all doses of Metformin DR) but with ~3-fold greater plasma metformin exposure. Normalizing efficacy to systemic exposure, glycemic improvements with Metformin DR were 1.5-fold (HbA1c) and 2.1-fold (FPG) greater than Metformin IR. Adverse events were primarily gastrointestinal but these were less frequent with Metformin DR (<16% incidence) vs. Metformin IR (28%), particularly nausea (1-3% vs 10%).

Conclusion: Metformin DR exhibited greater efficacy per unit plasma exposure than Metformin IR. Future studies will evaluate the effects of Metformin DR in patients with type 2 diabetes and advanced renal disease.

Trial registration: Clinicaltrials.gov NCT02526524.

Publication types

  • Multicenter Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Blood Glucose / analysis
  • Delayed-Action Preparations
  • Diabetes Mellitus, Type 2 / complications
  • Diabetes Mellitus, Type 2 / drug therapy*
  • Diabetic Nephropathies / drug therapy
  • Diabetic Nephropathies / metabolism
  • Double-Blind Method
  • Female
  • Glycated Hemoglobin / analysis
  • Humans
  • Hypoglycemic Agents / administration & dosage*
  • Hypoglycemic Agents / therapeutic use
  • Ileum / metabolism
  • Male
  • Metformin / administration & dosage*
  • Metformin / therapeutic use
  • Middle Aged

Substances

  • Blood Glucose
  • Delayed-Action Preparations
  • Glycated Hemoglobin A
  • Hypoglycemic Agents
  • hemoglobin A1c protein, human
  • Metformin

Associated data

  • ClinicalTrials.gov/NCT02526524

Grants and funding

This study was funded by Elcelyx Therapeutics, Inc. BW, SS, JH, CB, TAB, AB and MF are employed by Elcelyx Therapeutics, Inc. The sponsor (Elcelyx Therapeutics) contributed to study design, data collection, analysis, writing the report, and the decision to submit the report for publication.