Investigation of the Diagnostic Value of Ultrasonography for Radial Neuropathy Located at the Spiral Groove

Ann Rehabil Med. 2018 Aug;42(4):601-608. doi: 10.5535/arm.2018.42.4.601. Epub 2018 Aug 31.

Abstract

Objective: To determine a diagnostic cut-off value for the cross-sectional area (CSA) of the radial nerve using ultrasonography for radial neuropathy located at the spiral groove (SG).

Methods: Seventeen patients with electrodiagnostic evidence of radial neuropathy at the SG and 30 healthy controls underwent ultrasonography of the radial nerve at the SG . The CSAs at the SG were compared in the patient and control groups. The CSA at the SG between the symptomatic and asymptomatic sides (ΔSx-Asx and Sx/Asx, respectively) were analyzed to obtain the optimal cut-off value. The relationship between the electrophysiological severity of radial neuropathy and CSA was also evaluated.

Results: Among the variables examined, there were statistically significant differences in the CSA between the patient and control groups, ΔSx-Asx, and Sx/Asx at the SG. In a receiver operating characteristics analysis, the cut-off CSA was 5.75 mm2 at the SG (sensitivity 52.9%, specificity 90%), 1.75 mm2 for ΔSx-Asx (sensitivity 58.8%, specificity 100%), and 1.22 mm2 for Sx/Asx (sensitivity 70.6%, specificity 93.3%) in diagnosing radial neuropathy at the SG. There was no significant correlation between CSA and electrophysiological severity score for either patient group.

Conclusion: The reference value obtained for CSA of the radial nerve at the SG may facilitate investigation of radial nerve pathologies at the SG.

Keywords: Diagnostic imaging; Radial neuropathy.