Spectral-Domain OCT Measurements in Alzheimer's Disease: A Systematic Review and Meta-analysis

Ophthalmology. 2019 Apr;126(4):497-510. doi: 10.1016/j.ophtha.2018.08.009. Epub 2018 Aug 13.

Abstract

Topic: OCT is a noninvasive tool to measure specific retinal layers in the eye. The relationship of retinal spectral-domain (SD) OCT measurements with Alzheimer's disease (AD) and mild cognitive impairment (MCI) remains unclear. Hence, we conducted a systematic review and meta-analysis to examine the SD OCT measurements in AD and MCI.

Clinical relevance: Current methods of diagnosing early AD are expensive and invasive. Retinal measurements of SD OCT, which are noninvasive, technically simple, and inexpensive, are potential biomarkers of AD.

Methods: We conducted a literature search in PubMed and Excerpta Medica Database to identify studies published before December 31, 2017, that assessed the associations between AD, MCI, and measurements of SD OCT: ganglion cell-inner plexiform layer (GC-IPL), ganglion cell complex (GCC), macular volume, and choroidal thickness, in addition to retinal nerve fiber layer (RNFL) and macular thickness. We used a random-effects model to examine these relationships. We also conducted meta-regression and assessed heterogeneity, publication bias, and study quality.

Results: We identified 30 eligible studies, involving 1257 AD patients, 305 MCI patients, and 1460 controls, all of which were cross-sectional studies. In terms of the macular structure, AD patients showed significant differences in GC-IPL thickness (standardized mean difference [SMD], -0.46; 95% confidence interval [CI], -0.80 to -0.11; I2 = 71%), GCC thickness (SMD, -0.84; 95% CI, -1.10 to -0.57; I2 = 0%), macular volume (SMD, -0.58; 95% CI, -1.03 to -0.14; I2 = 80%), and macular thickness of all inner and outer sectors (SMD range, -0.52 to -0.74; all P < 0.001) when compared with controls. Peripapillary RNFL thickness (SMD, -0.67; 95% CI, -0.95 to -0.38; I2 = 89%) and choroidal thickness (SMD range, -0.88 to -1.03; all P < 0.001) also were thinner in AD patients.

Conclusions: Our results confirmed the associations between retinal measurements of SD OCT and AD, highlighting the potential usefulness of SD OCT measurements as biomarkers of AD.

Publication types

  • Meta-Analysis
  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't
  • Systematic Review

MeSH terms

  • Alzheimer Disease / diagnostic imaging*
  • Biomarkers
  • Cognitive Dysfunction / diagnostic imaging*
  • Cross-Sectional Studies
  • Humans
  • Nerve Fibers / pathology
  • Organ Size
  • Retina / diagnostic imaging
  • Retinal Diseases / diagnostic imaging*
  • Retinal Ganglion Cells / pathology
  • Tomography, Optical Coherence / methods*

Substances

  • Biomarkers