Electronic Monitoring Systems to Assess Urinary Incontinence: A Health Technology Assessment

Ont Health Technol Assess Ser. 2018 May 3;18(3):1-60. eCollection 2018.

Abstract

Background: Urinary incontinence is involuntary leakage of urine and can affect people of all ages. Incidence rises as people age, often because of reduced mobility or conditions affecting the nervous system, such as dementia and stroke. Urinary incontinence can be a distressing condition and can harm a person's physical, financial, social, and emotional well-being. People with urinary incontinence are susceptible to skin irritation, pressure sores, and urinary tract infections. Urinary incontinence is also associated with an increased risk of falls in older adults.This health technology assessment examined the effectiveness of, budget impact of, and patient values and preferences about electronic monitoring systems to assess urinary incontinence for residents of long-term care homes or geriatric hospital inpatients with complex conditions.

Methods: A clinical evidence review of the published clinical literature was conducted to June 9, 2017. Critical appraisal of the clinical evidence included assessment of risk of bias and the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) Working Group criteria to reflect the certainty of the evidence.We calculated the funding required for an electronic urinary incontinence monitoring system in the first year of implementation (when facilities would buy the systems) and in subsequent years.We interviewed six people with urinary incontinence and two caregivers, who described ways urinary incontinence affected daily life.

Results: We included one observational study in the clinical review. Most of the 31 participants in the observational study were female (78%) and required high levels of care, primarily because of cognitive impairment. The quality of evidence for all outcomes was very low owing to potential risk of bias and indirectness. We are consequently uncertain about how electronic monitoring systems affect management of urinary incontinence.For patients living in long-term care homes who are eligible for the technology, we estimated that an electronic monitoring system to assess urinary incontinence would cost $6.4 million in the first year of implementation and $1.6 million in subsequent years.Patients said urinary incontinence reduced their independence and social life and adversely affected their quality of life. Incontinence made them embarrassed and reduced their self-esteem. Several respondents mentioned how expensive supplies to manage incontinence were.

Conclusions: The effectiveness of using the electronic monitoring system to assess urinary incontinence is uncertain because of the very low quality of the evidence. Introducing electronic monitoring systems would result in incremental costs, and there would be savings only if the systems substantially reduced incontinence.

Publication types

  • Review

MeSH terms

  • Aged
  • Cost-Benefit Analysis
  • Geriatric Assessment / methods*
  • Health Care Costs
  • Humans
  • Long-Term Care / statistics & numerical data
  • Patient Preference
  • Patient Satisfaction
  • Quality of Life
  • Technology Assessment, Biomedical* / economics
  • Urinary Incontinence / diagnosis*