A Hem-o-Lok-Induced Tracheoesophageal Fistula Cured by Temporary Airway Stenting Modified With Three-Dimensional Printing

Ann Thorac Surg. 2018 Oct;106(4):e219-e221. doi: 10.1016/j.athoracsur.2018.04.037. Epub 2018 May 12.

Abstract

We present the case of a fistula between the trachea and the esophagogastric anastomosis in a 58-year-old man after esophagectomy. A Hem-o-Lok clip (Teleflex, Morrisville, NC) used at the time to ligate the azygos vein was discovered by esophagoscopy and bronchoscopy to be eroding into both structures. A covered self-expandable Y-shaped metallic tracheobronchial stent was customized with a three-dimensional printed airway model and inserted in place with endoscopic injection of fibrin glue to the anastomotic site. The stent was withdrawn 64 days after implantation, with complete healing of the fistula.

Publication types

  • Case Reports

MeSH terms

  • Bronchi / surgery*
  • Bronchoscopy / methods
  • Esophageal Neoplasms / surgery*
  • Esophagectomy / adverse effects*
  • Esophagoscopy
  • Humans
  • Male
  • Middle Aged
  • Printing, Three-Dimensional*
  • Prosthesis Design
  • Stents*
  • Trachea / surgery*
  • Tracheoesophageal Fistula / diagnosis
  • Tracheoesophageal Fistula / etiology
  • Tracheoesophageal Fistula / surgery*