An electrochemical immunoassay for Escherichia coli O157:H7 using double functionalized Au@Pt/SiO2 nanocomposites and immune magnetic nanoparticles

Talanta. 2018 May 15:182:354-362. doi: 10.1016/j.talanta.2018.01.095. Epub 2018 Feb 2.

Abstract

A sensitive Point-of-Care Testing (POCT) with Au-Pt bimetallic nanoparticles (Au@Pt) functionalized silica nanoparticle (SiO2 NPs) and Fe3O4 magnetic nanoparticles (Fe3O4 NPs) was designed for the quantitative detection of Escherichia coli O157:H7 (E. coli O157:H7). The poly-(4-styrenesulfonic acid-co-maleic acid) (PSSMA) as a negatively charged polyelectrolyte can be easily coated on surface of the amino group modified SiO2 NPs via electrostatic force. PSSMA is also a good stabilizer for water-soluble bimetallic nanostructures. The PSSMA is first time used as a "bridge" to connect the negative charge Au@Pt NPs to the SiO2 NPs, forming Au@Pt/SiO2 NPs. Antibody and invertase conjugated Au@Pt/SiO2 NPs (denoted as Ab/invertase-Au@Pt/SiO2 NPs) were used as signal labels. Monoclonal antibody against E. coli O157:H7 (Ab) functionalized magnetic nanoparticles (denoted as Ab-Fe3O4@SiO2 NPs) were used to enrich and capture the E. coli O157:H7 in positive sample. The immunosensing platform also composed of a personal glucometer (PGM) using for signal readout. Based on this sandwich-type immunoassay, the invertase in the final formed sandwich immunocomplex catalyzed the hydrolysis of sucrose to produce a large amount of glucose for quantitative readout by the PGM. Under optimal conditions, a linear relationship between the glucose concentration and the logarithm of E. coli O157:H7 concentration was obtained in the concentration range from 3.5 × 102 to 3.5 × 108 CFU mL-1 with a detection limit of 1.83 × 102 CFU mL-1 (3σ). This method was used to detect E. coli O157:H7 in spiked milk samples, indicating its potential practical application. This protocol can be applied in various fields of study.

Keywords: Bimetallic nanoparticles; Escherichia coli O157:H7; Invertase; Magnetic nanoparticles; Personal glucometer.

MeSH terms

  • Antibodies, Immobilized / chemistry
  • Antibodies, Monoclonal / chemistry
  • Biosensing Techniques*
  • Electrochemical Techniques*
  • Escherichia coli O157 / isolation & purification*
  • Escherichia coli O157 / metabolism
  • Ferrosoferric Oxide / chemistry
  • Glucose / chemistry
  • Gold / chemistry
  • Humans
  • Immunoassay*
  • Immunoconjugates / chemistry
  • Limit of Detection
  • Magnetite Nanoparticles / chemistry*
  • Magnetite Nanoparticles / ultrastructure
  • Maleates / chemistry
  • Nanocomposites / chemistry*
  • Nanocomposites / ultrastructure
  • Point-of-Care Systems
  • Polystyrenes / chemistry
  • Silicon Dioxide / chemistry
  • Static Electricity
  • Sucrose / chemistry
  • beta-Fructofuranosidase / chemistry

Substances

  • Antibodies, Immobilized
  • Antibodies, Monoclonal
  • Immunoconjugates
  • Magnetite Nanoparticles
  • Maleates
  • Polystyrenes
  • poly(4-styrenesulfonic acid-co-maleic acid)
  • Sucrose
  • Gold
  • Silicon Dioxide
  • beta-Fructofuranosidase
  • Glucose
  • Ferrosoferric Oxide