Reference Intervals of Cytokeratin-19 Fragment (CYFRA 21-1) in Healthy Adults in China

Clin Lab. 2018 Jan 1;64(1):123-133. doi: 10.7754/Clin.Lab.2017.170708.

Abstract

Background: The reference intervals for serum cytokeratin-19 fragment (CYFRA 21-1) have not been established in Chinese population. This study aimed to measure serum CYFRA 21-1 levels in healthy Chinese subjects.

Methods: This cross-sectional, four-center study in two Chinese provinces enrolled participants (aged 18 - 85 years) with normal liver/kidney function and normal results for routine blood tests/urinalysis. Serum CYFRA 211 level was measured by ARCHITECT immunoassay (Abbott Diagnostics).

Results: The study included 3,366 participants. The median (interquartile range) value for serum CYFRA 21-1 level was 1.38 (1.00 - 1.89) ng/mL and tended to increase with age. The upper limit of the 97.5th percentile was 3.55 ng/mL and tended to increase with age. Serum CYFRA 21-1 median level varied between the four centers from 1.22 (0.89, 1.71) to 1.55 (1.12, 2.18) ng/mL, while the 97.5th percentile varied from 3.24 to 4.09 ng/mL. CYFRA 21-1 level correlated weakly with age and creatinine level.

Conclusions: These new data can help to establish the 'normal range' of serum CYFRA 21-1 in people in China.

Publication types

  • Multicenter Study

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Antigens, Neoplasm / blood*
  • Biomarkers, Tumor / blood*
  • China
  • Cross-Sectional Studies
  • Humans
  • Keratin-19 / blood*
  • Middle Aged
  • Reference Values
  • Reproducibility of Results
  • Young Adult

Substances

  • Antigens, Neoplasm
  • Biomarkers, Tumor
  • Keratin-19
  • antigen CYFRA21.1