Subject-specific pulse wave propagation modeling: Towards enhancement of cardiovascular assessment methods

PLoS One. 2018 Jan 11;13(1):e0190972. doi: 10.1371/journal.pone.0190972. eCollection 2018.

Abstract

Cardiovascular diseases are the leading cause of death worldwide. Pulse wave analysis (PWA) technique, which reconstructs and analyses aortic pressure waveform based on non-invasive peripheral pressure recording, became an important bioassay for cardiovascular assessment in a general population. The aim of our study was to establish a pulse wave propagation modeling framework capable of matching clinical PWA data from healthy individuals on a per-subject basis. Radial pressure profiles from 20 healthy individuals (10 males, 10 females), with mean age of 42 ± 10 years, were recorded using applanation tonometry (SphygmoCor, AtCor Medical, Australia) and used to estimate subject-specific parameters of mathematical model of blood flow in the system of fifty-five arteries. The model was able to describe recorded pressure profiles with high accuracy (mean absolute percentage error of 1.87 ± 0.75%) when estimating only 6 parameters for each subject. Cardiac output (CO) and stroke volume (SV) have been correctly identified by the model as lower in females than males (CO of 3.57 ± 0.54 vs. 4.18 ± 0.72 L/min with p-value < 0.05; SV of 49.5 ± 10.1 vs. 64.2 ± 16.8 ml with p-value = 0.076). Moreover, the model identified age related changes in the heart function, i.e. that the cardiac output at rest is maintained with age (r = 0.23; p-value = 0.32) despite the decreasing heart rate (r = -0.49; p-value < 0.05), because of the increase in stroke volume (r = 0.46; p-value < 0.05). Central PWA indices derived from recorded waveforms strongly correlated with those obtained using corresponding model-predicted radial waves (r > 0.99 and r > 0.97 for systolic (SP) and diastolic (DP) pressures, respectively; r > 0.77 for augmentation index (AI); all p-values < 0.01). Model-predicted central waveforms, however, had higher SP than those reconstructed by PWA using recorded radial waves (5.6 ± 3.3 mmHg on average). From all estimated subject-specific parameters only the time to the peak of heart ejection profile correlated with clinically measured AI. Our study suggests that the proposed model may serve as a tool to computationally investigate virtual patient scenarios mimicking different cardiovascular abnormalities. Such a framework can augment our understanding and help with the interpretation of PWA results.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Cardiovascular Physiological Phenomena*
  • Female
  • Humans
  • Male
  • Middle Aged
  • Models, Biological
  • Pulse Wave Analysis*

Grants and funding

The study was supported by the National Science Centre (Poland), grant No. 2013/11/B/ST7/01704. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.