Measurement of Lipoprotein-Associated Phospholipase A2 by Use of 3 Different Methods: Exploration of Discordance between ELISA and Activity Assays

Clin Chem. 2018 Apr;64(4):697-704. doi: 10.1373/clinchem.2017.279752. Epub 2018 Jan 10.

Abstract

Background: Lipoprotein-associated phospholipase A2 (Lp-PLA2), an enzyme associated with inflammation, is used as a biomarker for cardiovascular disease risk. Both the concentration and activity of Lp-PLA2 have been shown to be clinically relevant. However, there is a discordance between the serum concentration of Lp-PLA2 measured by the standard ELISA-based immunoassays and the activity of this enzyme, leading to substantial discordance in risk categorization depending on assay format.

Methods: We developed 2 LC-MS/MS-based assays to quantify serum Lp-PLA2 activity (multiple reaction monitoring detection of product) and concentration [stable isotope standards and capture by antipeptide antibody (SISCAPA) immunoaffinity], and we investigated their correlation to commercially offered colorimetric activity and immunometric concentrations assays. Associations between Lp-PLA2 and lipoproteins and the effect of selected detergents in liberating Lp-PLA2 were evaluated by use of immunoprecipitation and Western blot analyses.

Results: Serum Lp-PLA2 concentrations measured by quantitative SISCAPA-mass spectrometry were substantially higher than concentrations typically measured by immunoassay and showed an improved agreement with Lp-PLA2 activity. With detergents, liberation of Lp-PLA2 from lipoprotein complexes dramatically increased the amount of protein detected by immunoassay and improved the agreement with activity measurements.

Conclusions: Quantitative analysis of Lp-PLA2 concentration and activity by LC-MS/MS assays provided key insight into resolving the well-documented discordance between Lp-PLA2 concentration (determined by immunoassay) and activity. Quantitative detection of Lp-PLA2 by immunoassay appears to be strongly inhibited by interaction of Lp-PLA2 with lipoprotein. Together, the results illustrate the advantages of quantitative LC-MS/MS for measurement of Lp-PLA2 concentration (by SISCAPA) and activity (by direct product detection).

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • 1-Alkyl-2-acetylglycerophosphocholine Esterase / blood*
  • Blotting, Western
  • Cholesterol / blood
  • Chromatography, Liquid / methods*
  • Detergents / chemistry
  • Enzyme-Linked Immunosorbent Assay / methods*
  • Humans
  • Immunoprecipitation
  • Lipoproteins / blood
  • Tandem Mass Spectrometry / methods*

Substances

  • Detergents
  • Lipoproteins
  • lipoprotein cholesterol
  • Cholesterol
  • 1-Alkyl-2-acetylglycerophosphocholine Esterase