Seven patients with severe aortic stenosis underwent percutaneous aortic balloon valvuloplasty in preparation for major noncardiac surgery. There were four men and three women (mean age 82 +/- 1.3 years, range 78 to 88). A significant reduction in the transaortic pressure gradient from 77 +/- 7.8 to 31 +/- 6.2 mm Hg (p = 0.002) and increase in calculated aortic valve area from 0.5 +/- 0.1 to 1.0 +/- 0.3 cm2 (p = 0.05) was noted. Three of the seven procedures were performed anterograde with use of transseptal puncture: two of the three because of abdominal aortic aneurysm and one because of peripheral vascular disease. All seven patients underwent uncomplicated noncardiac surgery under general anesthesia 10 +/- 4.3 days (range 0 to 29) after aortic valvuloplasty. One patient had exploratory laparotomy, one underwent stabilization of a hip fracture and two underwent resection of an abdominal aortic aneurysm. Of the three other patients who underwent colectomy, one had repeat aortic valvuloplasty and repair of a hip fracture 7 months later and one required exploratory laparotomy without repeat valvuloplasty 7 weeks later. Percutaneous aortic balloon valvuloplasty is an effective and safe procedure that may reduce the risk of general anesthesia and major noncardiac surgery in elderly patients with aortic stenosis.