Cardiac and respiratory-gated volumetric murine ultrasound

Int J Cardiovasc Imaging. 2018 May;34(5):713-724. doi: 10.1007/s10554-017-1283-z. Epub 2017 Dec 12.

Abstract

Current cardiovascular ultrasound mainly employs planar imaging techniques to assess function and physiology. These techniques rely on geometric assumptions, which are dependent on the imaging plane, susceptible to inter-observer variability, and may be inaccurate when studying complex diseases. Here, we developed a gated volumetric murine ultrasound technique to visualize cardiovascular motion with high spatiotemporal resolution and directly evaluate cardiovascular health. Cardiac and respiratory-gated cine loops, acquired at 1000 frames-per-second from sequential positions, were temporally registered to generate a four-dimensional (4D) dataset. We applied this technique to (1) evaluate left ventricular (LV) function from both healthy mice and mice with myocardial infarction and (2) characterize aortic wall strain of angiotensin II-induced dissecting abdominal aortic aneurysms in apolipoprotein E-deficient mice. Combined imaging and processing times for the 4D technique was approximately 2-4 times longer than conventional 2D approaches, but substantially more data is collected with 4D ultrasound and further optimization can be implemented to reduce imaging times. Direct volumetric measurements of 4D cardiac data aligned closely with those obtained from MRI, contrary to conventional methods, which were sensitive to transducer alignment, leading to overestimation or underestimation of estimated LV parameters in infarcted hearts. Green-Lagrange circumferential strain analysis revealed higher strain values proximal and distal to the aneurysm than within the aneurysmal region, consistent with published reports. By eliminating the need for geometrical assumptions, the presented 4D technique can be used to more accurately evaluate cardiac function and aortic pulsatility. Furthermore, this technique allows for the visualization of regional differences that may be overlooked with conventional 2D approaches.

Keywords: Abdominal aortic aneurysm; Animal models and imaging; Aortic dissection; Circumferential strain; Myocardial infarction; Ultrasound; Volumetric imaging.

Publication types

  • Comparative Study

MeSH terms

  • Angiotensin II
  • Animals
  • Aorta, Abdominal / diagnostic imaging*
  • Aorta, Abdominal / physiopathology
  • Aortic Aneurysm, Abdominal / chemically induced
  • Aortic Aneurysm, Abdominal / diagnostic imaging*
  • Aortic Aneurysm, Abdominal / genetics
  • Aortic Aneurysm, Abdominal / physiopathology
  • Aortic Dissection / chemically induced
  • Aortic Dissection / diagnostic imaging*
  • Aortic Dissection / genetics
  • Aortic Dissection / physiopathology
  • Biomechanical Phenomena
  • Cardiac-Gated Imaging Techniques*
  • Disease Models, Animal
  • Echocardiography, Four-Dimensional*
  • Heart Ventricles / diagnostic imaging*
  • Heart Ventricles / physiopathology
  • Image Interpretation, Computer-Assisted
  • Magnetic Resonance Imaging
  • Male
  • Mice, Inbred C57BL
  • Mice, Knockout, ApoE
  • Myocardial Infarction / diagnostic imaging*
  • Myocardial Infarction / physiopathology
  • Predictive Value of Tests
  • Reproducibility of Results
  • Respiratory-Gated Imaging Techniques*
  • Vascular Stiffness
  • Ventricular Function, Left

Substances

  • Angiotensin II