Combined Partial Penectomy With Bilateral Robotic Inguinal Lymphadenectomy Using Near-infrared Fluorescence Guidance

Urology. 2018 Mar:113:251. doi: 10.1016/j.urology.2017.11.021. Epub 2017 Nov 27.

Abstract

Objective: To describe our novel technique for performing a combined partial penectomy and bilateral robotic inguinal lymphadenectomy using intraoperative near-infrared (NIR) fluorescence guidance with indocyanine green (ICG) and the DaVinci Firefly camera system.

Methods: A 58-year-old man presented status post recent excisional biopsy of a 2-cm lesion on the left coronal aspect of the glans penis. Pathology revealed "invasive squamous cell carcinoma of the penis with multifocal positive margins." His examination was suspicious for cT2 primary and his inguinal nodes were cN0. He was counseled to undergo partial penectomy with possible combined vs staged bilateral robotic inguinal lymphadenectomy. Preoperative computed tomography scan was negative for pathologic lymphadenopathy. Before incision, 5 mL of ICG was injected subcutaneously beneath the tumor. Bilateral thigh pockets were then developed simultaneously and a right, then left robotic modified inguinal lymphadenectomy was performed using NIR fluorescence guidance via the DaVinci Firefly camera. A partial penectomy was then performed in the standard fashion.

Results: The combined procedure was performed successfully without complication. Total operative time was 379 minutes and total robotic console time was 95 minutes for the right and 58 minutes to the left. Estimated blood loss on the right and left were 15 and 25 mL, respectively. A total of 24 lymph nodes were retrieved.

Conclusion: This video demonstrates a safe and feasible approach for combined partial penectomy and bilateral inguinal lymphadenectomy with NIR guidance using ICG and the DaVinci Firefly camera system. The combined robotic approach has minimal morbidity and avoids the need for a staged procedure. Furthermore, use of NIR guidance with ICG during robotic inguinal lymphadenectomy is feasible and may help identify sentinel lymph nodes and improve the quality of dissection. Further studies are needed to confirm the utility of NIR guidance for robotic sentinel lymph node dissection.

Publication types

  • Case Reports

MeSH terms

  • Carcinoma, Squamous Cell / pathology
  • Carcinoma, Squamous Cell / surgery*
  • Combined Modality Therapy
  • Follow-Up Studies
  • Humans
  • Indocyanine Green
  • Inguinal Canal
  • Lymph Node Excision / methods*
  • Male
  • Middle Aged
  • Neoplasm Invasiveness / pathology
  • Neoplasm Staging
  • Penile Neoplasms / pathology
  • Penile Neoplasms / surgery*
  • Robotic Surgical Procedures / methods*
  • Spectroscopy, Near-Infrared / methods*
  • Surgery, Computer-Assisted / methods*
  • Treatment Outcome
  • Urologic Surgical Procedures, Male / instrumentation
  • Urologic Surgical Procedures, Male / methods

Substances

  • Indocyanine Green