Two-dimensional speckle-tracking global longitudinal strain in high-sensitivity troponin-negative low-risk patients with unstable angina: a "resting ischemia test"?

Int J Cardiovasc Imaging. 2018 Apr;34(4):561-568. doi: 10.1007/s10554-017-1269-x. Epub 2017 Nov 11.

Abstract

With the introduction of high-sensitivity troponin (hsTNI) assays, the clinical significance unstable angina (UA) has become uncertain. We hypothesized that impaired left ventricular (LV) two-dimensional speckle-tracking echocardiography (2D-STE)-derived peak global longitudinal strain (GLS) was able to exclude the presence of significant coronary artery disease (CAD) in UA patients without prior cardiovascular (CV) events and with a normal LV ejection fraction (LVEF). From a cohort of 200 patients admitted with UA, we selected 61 patients without prior CV events and with a normal LVEF; of these, 48 (79%) underwent invasive coronary angiography (ICA) and 24 (39%) had at least ≥ 1 significant stenosis. 2D-STE LV GLS analysis was performed offline using a dedicated automated software program. The mean patient age was 61 ± 12 years and 66% were male. Among the 48 patients selected to undergo ICA, those without significant CAD had a better 2D-STE GLS (- 19.4 vs. - 15.9%, P < 0.001). A cutoff of - 17.5% had a sensitivity of 87% and a specificity of 82% for differentiating UA patients without significant stenosis (AUC 0.86, P < 0.001). Patients who did not undergo ICA had a better GLS (- 20.2 vs. - 17.7%, P = 0.017). 2D-STE GLS had a significantly better discriminative power compared with LVEF (P < 0.001) and the GRACE score (P < 0.001) for identifying patients with significant CAD. Impaired values of 2D-STE LV GLS were significantly associated with the presence of CAD in hsTnI-negative UA patients and demonstrated better discriminative power than LVEF and the GRACE score.

Keywords: Ischemia testing; Left ventricular strain; Unstable angina.

MeSH terms

  • Aged
  • Angina, Unstable / blood
  • Angina, Unstable / diagnostic imaging*
  • Angina, Unstable / physiopathology
  • Area Under Curve
  • Biomarkers / blood
  • Biomechanical Phenomena
  • Coronary Angiography
  • Coronary Stenosis / blood
  • Coronary Stenosis / diagnostic imaging*
  • Coronary Stenosis / physiopathology
  • Disease-Free Survival
  • Echocardiography / methods*
  • Female
  • Humans
  • Male
  • Middle Aged
  • Myocardial Contraction*
  • Observer Variation
  • Predictive Value of Tests
  • ROC Curve
  • Reproducibility of Results
  • Retrospective Studies
  • Severity of Illness Index
  • Stroke Volume
  • Troponin I / blood*
  • Ventricular Function, Left*

Substances

  • Biomarkers
  • Troponin I