The Detection of Water Flow in Rectangular Microchannels by Terahertz Time Domain Spectroscopy

Sensors (Basel). 2017 Oct 13;17(10):2330. doi: 10.3390/s17102330.

Abstract

Flow characteristics of water were tested in a rectangular microchannel for Reynolds number (Re) between 0 and 446 by terahertz time domain spectroscopy (THz-TDS). Output THz peak trough intensities and the calculated absorbances of the flow were analyzed theoretically. The results show a rapid change for Re < 250 and a slow change as Re increases, which is caused by the early transition from laminar to transition flow beginning nearly at Re = 250. Then this finding is confirmed in the plot of the flow resistant. Our results demonstrate that the THz-TDS could be a valuable tool to monitor and character the flow performance in microscale structures.

Keywords: THz-TDS; flow resistance; flow-rate; pressure drop; rectangular microchannel; water flow.