An optical coherence tomography study of neointimal morphology and strut coverage at different time intervals from implantation of biodegradable polymer-coated sirolimus-eluting stents

Catheter Cardiovasc Interv. 2018 Aug 1;92(2):302-309. doi: 10.1002/ccd.27374. Epub 2017 Oct 13.

Abstract

Objectives: The aim of the study was to capture the evolution of neointima after implantation of a biodegradable polymer-coated, sirolimus-eluting, cobalt-chromium coronary stent system (BP-DES).

Background: Optical coherence tomography (OCT) suggests that in-stent neointimal morphology influences clinical outcomes after DES implantation.

Methods: Sixty patients treated with single BP-DES implantation were examined by quantitative coronary angiography (QCA) and OCT at 3, 6, and 12-month follow-up.

Results: Median late lumen loss by QCA (mm) was 0.04 (IQR 0, 0.08), 0.17 (IQR 0, 0.32), and 0.14 (IQR 0.07, 0.31) at 3, 6, and 12-month follow-up respectively (P = 0.03). OCT cross-section multilevel analysis showed uncovered struts in 3.90%, 1.78%, and 0.02% of struts respectively (P = 0.03). The corresponding malapposition rates were 0.12%, 0.04%, and 0%. Lipid-rich neointima was observed only at 12-month follow-up in one restenotic lesion (0.77% cross-sections) that was accountable for the only target vessel revascularization. The homogeneous pattern was prevalent at all three time points, but its incidence displayed an upward trend (3 months: 59%; 6 months: 71%; 12 months: 88%) despite no difference in neointimal volume between 6 and 12 months. Conversely, a trend could be observed of decreasing incidence of heterogeneous pattern as the follow-up length increased.

Conclusions: In this study of a single-type BP-DES, the majority of stent struts were covered within 3 months from implantation. While the quantitative neointimal accumulation plateaued at 6 months with no further significant increase beyond 6 months, the neointima continued to evolve qualitatively and mature along with better strut coverage between 6 and 12 months after implantation.

Keywords: coronary artery disease; drug-eluting stent; optical imaging.

Publication types

  • Multicenter Study

MeSH terms

  • Absorbable Implants*
  • Aged
  • Cardiovascular Agents / administration & dosage*
  • Cardiovascular Agents / adverse effects
  • Chromium Alloys
  • Coronary Angiography
  • Coronary Artery Disease / diagnostic imaging
  • Coronary Artery Disease / surgery*
  • Coronary Vessels / diagnostic imaging
  • Coronary Vessels / surgery*
  • Drug-Eluting Stents*
  • Female
  • Humans
  • Male
  • Middle Aged
  • Neointima*
  • Percutaneous Coronary Intervention / adverse effects
  • Percutaneous Coronary Intervention / instrumentation*
  • Poland
  • Predictive Value of Tests
  • Prospective Studies
  • Prosthesis Design
  • Risk Factors
  • Sirolimus / administration & dosage*
  • Sirolimus / adverse effects
  • Time Factors
  • Tomography, Optical Coherence*
  • Treatment Outcome

Substances

  • Cardiovascular Agents
  • Chromium Alloys
  • Sirolimus