Working Memory Capacity and Surgical Performance While Exposed to Mild Hypoxic Hypoxemia

Aerosp Med Hum Perform. 2017 Oct 1;88(10):918-923. doi: 10.3357/AMHP.4761.2017.

Abstract

Introduction: Medical Emergency Response Team (MERT) helicopters fly at altitudes of 3000 m in Afghanistan (9843 ft). Civilian hospitals and disaster-relief surgical teams may have to operate at such altitudes or even higher. Mild hypoxia has been seen to affect the performance of novel tasks at flight levels as low as 5000 ft. Aeromedical teams frequently work in unpressurized environments; it is important to understand the implications of this mild hypoxia and investigate whether supplementary oxygen systems are required for some or all of the team members.

Methods: Ten UK orthopedic surgeons were recruited and in a double blind randomized experimental protocol, were acutely exposed for 45 min to normobaric hypoxia [fraction of inspired oxygen (FIo2) ∼14.1%, equivalent to 3000 m (10,000 ft)] or normobaric normoxia (sea-level). Basic physiological parameters were recorded. Subjects completed validated tests of verbal working memory capacity (VWMC) and also applied an orthopedic external fixator (Hoffmann® 3, Stryker, UK) to a plastic tibia under test conditions.

Results: Significant hypoxia was induced with the reduction of FIo2 to ∼14.1% (Spo2 87% vs. 98%). No effect of hypoxia on VWMC was observed. The pin-divergence score (a measure of frame asymmetry) was significantly greater in hypoxic conditions (4.6 mm) compared to sea level (3.0 mm); there was no significant difference in the penetrance depth (16.9 vs. 17.2 mm). One hypoxic frame would have failed early.

Discussion: We believe that surgery at an altitude of 3000 m, when unacclimated individuals are acutely exposed to atmospheric hypoxia for 45 min, can likely take place without supplemental oxygen use but further work is required.Parker PJ, Manley AJ, Shand R, O'Hara JP, Mellor A. Working memory capacity and surgical performance while exposed to mild hypoxic hypoxemia. Aerosp Med Hum Perform. 2017; 88(10):918-923.

Publication types

  • Randomized Controlled Trial

MeSH terms

  • Altitude
  • Double-Blind Method
  • External Fixators*
  • Fracture Fixation*
  • Humans
  • Hypoxia / physiopathology*
  • Memory, Short-Term / physiology*
  • Orthopedic Surgeons*
  • Task Performance and Analysis*
  • United Kingdom