Animal Models for Tendon Repair Experiments: A Comparison of Pig, Sheep and Human Deep Flexor Tendons in Zone II

J Hand Surg Asian Pac Vol. 2017 Sep;22(3):329-336. doi: 10.1142/S0218810417500381.

Abstract

Background: This laboratory study compared pig, sheep and human deep flexor tendons in regards to their biomechanical comparability.

Methods: To investigate the relevant biomechanical properties for tendon repair experiments, the tendons resistance to cheese-wiring (suture drag/splitting) was assessed. Cheese-wiring of a suture through a tendon is an essential factor for repair gapping and failure in a tendon repair.

Results: Biomechanical testing showed that forces required to pulling a uniform suture loop through sheep or pig tendons in Zone II were higher than in human tendons. At time point zero of testing these differences did not reach statistical significance, but differences became more pronounced when forces were measured beyond initial cheese-wiring (2 mm, 5 mm and 10 mm). The stronger resistance to cheese-wiring was more pronounced in the pig tendons. Also regarding size and histology, sheep tendons were more comparable to human tendons than pig tendons.

Conclusions: Differences in tendon bio-properties should be kept in mind when comparing and interpreting the results of laboratory tendon experiments.

Keywords: Biomechanical testing; Deep flexor tendon; Pig tendon; Sheep tendon; Tendon repair.

Publication types

  • Comparative Study

MeSH terms

  • Animals
  • Cadaver
  • Disease Models, Animal
  • Humans
  • Sheep
  • Suture Techniques*
  • Sutures
  • Swine
  • Tendon Injuries / surgery*
  • Tensile Strength