Development of a bedside viable ultrasound protocol to quantify appendicular lean tissue mass

J Cachexia Sarcopenia Muscle. 2017 Oct;8(5):713-726. doi: 10.1002/jcsm.12213. Epub 2017 Jul 19.

Abstract

Background: Ultrasound is a non-invasive and readily available tool that can be prospectively applied at the bedside to assess muscle mass in clinical settings. The four-site protocol, which images two anatomical sites on each quadriceps, may be a viable bedside method, but its ability to predict musculature has not been compared against whole-body reference methods. Our primary objectives were to (i) compare the four-site protocol's ability to predict appendicular lean tissue mass from dual-energy X-ray absorptiometry; (ii) optimize the predictability of the four-site protocol with additional anatomical muscle thicknesses and easily obtained covariates; and (iii) assess the ability of the optimized protocol to identify individuals with low lean tissue mass.

Methods: This observational cross-sectional study recruited 96 university and community dwelling adults. Participants underwent ultrasound scans for assessment of muscle thickness and whole-body dual-energy X-ray absorptiometry scans for assessment of appendicular lean tissue. Ultrasound protocols included (i) the nine-site protocol, which images nine anterior and posterior muscle groups in supine and prone positions, and (ii) the four-site protocol, which images two anterior sites on each quadriceps muscle group in a supine position.

Results: The four-site protocol was strongly associated (R2 = 0.72) with appendicular lean tissue mass, but Bland-Altman analysis displayed wide limits of agreement (-5.67, 5.67 kg). Incorporating the anterior upper arm muscle thickness, and covariates age and sex, alongside the four-site protocol, improved the association (R2 = 0.91) with appendicular lean tissue and displayed narrower limits of agreement (-3.18, 3.18 kg). The optimized protocol demonstrated a strong ability to identify low lean tissue mass (area under the curve = 0.89).

Conclusions: The four-site protocol can be improved with the addition of the anterior upper arm muscle thickness, sex, and age when predicting appendicular lean tissue mass. This optimized protocol can accurately identify low lean tissue mass, while still being easily applied at the bedside.

Keywords: Appendicular lean tissue mass; Body composition; Muscle mass; Muscle thickness; Sarcopenia; Ultrasound.

MeSH terms

  • Absorptiometry, Photon
  • Adult
  • Aged
  • Body Composition*
  • Body Mass Index
  • Female
  • Humans
  • Male
  • Middle Aged
  • Muscle, Skeletal / anatomy & histology
  • Muscle, Skeletal / diagnostic imaging*
  • Muscle, Skeletal / pathology
  • Organ Size
  • ROC Curve
  • Reproducibility of Results
  • Sarcopenia / diagnostic imaging
  • Sarcopenia / etiology
  • Sarcopenia / pathology
  • Ultrasonography* / methods
  • Young Adult