Successful Transcatheter Aortic Valve Replacement for Severe Aortic Valve Regurgitation Following a David I Valve-Sparing Procedure

JACC Cardiovasc Interv. 2017 Jun 12;10(11):e101-e103. doi: 10.1016/j.jcin.2017.03.035. Epub 2017 May 17.
No abstract available

Keywords: aortic regurgitation; transcatheter aortic valve implantation; valve sparing aortic repair.

Publication types

  • Case Reports

MeSH terms

  • Adult
  • Aortic Aneurysm / diagnostic imaging
  • Aortic Aneurysm / etiology
  • Aortic Aneurysm / physiopathology
  • Aortic Aneurysm / surgery*
  • Aortic Valve / diagnostic imaging
  • Aortic Valve / physiopathology
  • Aortic Valve / surgery*
  • Aortic Valve Insufficiency / diagnostic imaging
  • Aortic Valve Insufficiency / etiology
  • Aortic Valve Insufficiency / physiopathology
  • Aortic Valve Insufficiency / surgery*
  • Aortography / methods
  • Blood Vessel Prosthesis
  • Blood Vessel Prosthesis Implantation* / instrumentation
  • Computed Tomography Angiography
  • Echocardiography, Doppler, Color
  • Echocardiography, Three-Dimensional
  • Echocardiography, Transesophageal
  • Female
  • Heart Valve Prosthesis
  • Humans
  • Marfan Syndrome / complications*
  • Marfan Syndrome / diagnosis
  • Prosthesis Design
  • Severity of Illness Index
  • Transcatheter Aortic Valve Replacement* / instrumentation
  • Treatment Outcome