Isotropic three-dimensional T2 mapping of knee cartilage: Development and validation

J Magn Reson Imaging. 2018 Feb;47(2):362-371. doi: 10.1002/jmri.25755. Epub 2017 May 10.

Abstract

Purpose: 1) To implement a higher-resolution isotropic 3D T2 mapping technique that uses sequential T2 -prepared segmented gradient-recalled echo (Iso3DGRE) images for knee cartilage evaluation, and 2) to validate it both in vitro and in vivo in healthy volunteers and patients with knee osteoarthritis.

Materials and methods: The Iso3DGRE sequence with an isotropic 0.6 mm spatial resolution was developed on a clinical 3T MR scanner. Numerical simulations were performed to optimize the pulse sequence parameters. A phantom study was performed to validate the T2 estimation accuracy. The repeatability of the sequence was assessed in healthy volunteers (n = 7). T2 values were compared with those from a clinical standard 2D multislice multiecho (MSME) T2 mapping sequence in knees of healthy volunteers (n = 13) and in patients with knee osteoarthritis (OA, n = 5).

Results: The numerical simulations resulted in 100 excitations per segment and an optimal radiofrequency (RF) excitation angle of 15°. The phantom study demonstrated a good correlation of the technique with the reference standard (slope 0.9 ± 0.05, intercept 0.2 ± 1.7 msec, R2 ≥ 0.99). Repeated measurements of cartilage T2 values in healthy volunteers showed a coefficient of variation of 5.6%. Both Iso3DGRE and MSME techniques found significantly higher cartilage T2 values (P < 0.03) in OA patients. Iso3DGRE precision was equal to that of the MSME T2 mapping in healthy volunteers, and significantly higher in OA (P = 0.01).

Conclusion: This study successfully demonstrated that high-resolution isotropic 3D T2 mapping for knee cartilage characterization is feasible, accurate, repeatable, and precise. The technique allows for multiplanar reformatting and thus T2 quantification in any plane of interest.

Level of evidence: 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:362-371.

Keywords: 3T; T2 mapping; isotropic 3D; knee cartilage; osteoarthritis.

Publication types

  • Research Support, Non-U.S. Gov't
  • Validation Study

MeSH terms

  • Adult
  • Aged
  • Cartilage, Articular / diagnostic imaging*
  • Cartilage, Articular / pathology
  • Cross-Sectional Studies
  • Feasibility Studies
  • Female
  • Humans
  • Image Interpretation, Computer-Assisted / methods*
  • Imaging, Three-Dimensional / methods*
  • Knee Joint / diagnostic imaging*
  • Knee Joint / pathology
  • Magnetic Resonance Imaging / methods*
  • Male
  • Middle Aged
  • Osteoarthritis, Knee / diagnostic imaging*
  • Osteoarthritis, Knee / pathology
  • Phantoms, Imaging
  • Reproducibility of Results
  • Sensitivity and Specificity