Incompatible type A plasma transfusion in patients requiring massive transfusion protocol: Outcomes of an Eastern Association for the Surgery of Trauma multicenter study

J Trauma Acute Care Surg. 2017 Jul;83(1):25-29. doi: 10.1097/TA.0000000000001532.

Abstract

With a relative shortage of type AB plasma, many centers have converted to type A plasma for resuscitation of patients whose blood type is unknown. The goal of this study is to determine outcomes for trauma patients who received incompatible plasma transfusions as part of a massive transfusion protocol (MTP).

Methods: As part of an Eastern Association for the Surgery of Trauma multi-institutional trial, registry and blood bank data were collected from eight trauma centers for trauma patients (age, ≥ 15 years) receiving emergency release plasma transfusions as part of MTPs from January 2012 to August 2016. Incompatible type A plasma was defined as transfusion to patient blood type B or type AB.

Results: Of the 1,536 patients identified, 92% received compatible plasma transfusions and 8% received incompatible type A plasma. Patient characteristics were similar except for greater penetrating injuries (48% vs 36%; p = 0.01) in the incompatible group. In the incompatible group, patients were transfused more plasma units at 4 hours (median, 9 vs. 5; p < 0.001) and overall for stay (11 vs. 9; p = 0.03). No hemolytic transfusion reactions were reported. Two transfusion-related acute lung injury events were reported in the compatible group. Between incompatible and compatible groups, there was no difference in the rates of acute respiratory distress syndrome (6% vs. 8%; p = 0.589), thromboembolic events (9% vs. 7%; p = 0.464), sepsis (6% vs. 8%; p = 0.589), or acute renal failure (8% vs. 8%, p = 0.860). Mortality at 6 (17% vs. 15%, p = 0.775) and 24 hours (25% vs. 23%, p = 0.544) and at 28 days or discharge (38% vs. 35%, p = 0.486) were similar between groups. Multivariate regression demonstrated that Injury Severity Score, older age and more red blood cell transfusion at 4 hours were independently associated with death at 28 days or discharge; Injury Severity Score and more red blood cell transfusion at 4 hours were predictors for morbidity. Incompatible transfusion was not an independent determinant of mortality or morbidity.

Conclusion: Transfusion of type A plasma to patients with blood groups B and AB as part of a MTP does not appear to be associated with significant increases in morbidity or mortality.

Level of evidence: Therapeutic study, level IV.

Publication types

  • Multicenter Study

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aged, 80 and over
  • Blood Component Transfusion / methods*
  • Blood Group Incompatibility*
  • Female
  • Hemorrhage / mortality
  • Hemorrhage / therapy*
  • Humans
  • Injury Severity Score
  • Male
  • Middle Aged
  • Plasma*
  • Registries
  • Resuscitation / methods*
  • Retrospective Studies
  • Risk Factors
  • Trauma Centers
  • Treatment Outcome
  • United States
  • Wounds and Injuries / mortality
  • Wounds and Injuries / therapy*