Therapeutic exchange with reconstituted whole blood using plasma exchange kit on a cell separator in G6PD deficient patient requiring red cell exchange for methemoglobinemia

J Clin Apher. 2017 Dec;32(6):597-598. doi: 10.1002/jca.21526. Epub 2017 Feb 7.
No abstract available

Publication types

  • Case Reports
  • Letter

MeSH terms

  • Cell Separation / instrumentation
  • Erythrocyte Transfusion / methods*
  • Exchange Transfusion, Whole Blood / methods*
  • Glucosephosphate Dehydrogenase Deficiency / therapy*
  • Humans
  • Male
  • Methemoglobinemia / therapy*
  • Plasma Exchange / methods*