Impact of Mandibular Advancement Therapy on Endothelial Function in Severe Obstructive Sleep Apnea

Am J Respir Crit Care Med. 2017 May 1;195(9):1244-1252. doi: 10.1164/rccm.201609-1817OC.

Abstract

Rationale: Endothelial dysfunction, a major predictor of late cardiovascular events, is linked to the severity of obstructive sleep apnea (OSA).

Objectives: To determine whether treatment with mandibular advancement device, the main alternative to continuous positive airway pressure, improves endothelial function in patients with severe OSA.

Methods: In this trial, we randomized patients with severe OSA and no overt cardiovascular disease to receive 2 months of treatment with either effective mandibular advancement device or a sham device. The primary outcome, change in reactive hyperemia index, a validated measurement of endothelial function, was assessed on an intention-to-treat basis. An embedded microsensor objectively measured treatment compliance.

Measurements and main results: A total of 150 patients (86% males; mean [SD] age, 54 [10] yr; median [interquartile range] apnea-hypopnea index, 41 [35-53]; mean [SD] Epworth sleepiness scale, 9.3 [4.2]) were randomized to effective mandibular advancement device (n = 75) or sham device (n = 75). On intention-to-treat analysis, effective mandibular advancement device therapy was not associated with improvement of endothelial function compared with the sham device. Office and ambulatory blood pressure outcomes did not differ between the two groups. Effective mandibular advancement device therapy was associated with significant improvements in apnea-hypopnea index (P < 0.001); microarousal index (P = 0.008); and symptoms of snoring, fatigue, and sleepiness (P < 0.001). Mean (SD) objective compliance was 6.6 (1.4) h/night with the effective mandibular advancement device versus 5.6 (2.3) h/night with the sham device (P = 0.006).

Conclusions: In moderately sleepy patients with severe OSA, mandibular advancement therapy reduced OSA severity and related symptoms but had no effect on endothelial function and blood pressure despite high treatment compliance. Clinical trial registered with www.clinicaltrials.gov (NCT 01426607).

Trial registration: ClinicalTrials.gov NCT01426607.

Keywords: endothelial function; mandibular advancement device; obstructive sleep apnea.

Publication types

  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Acute Disease
  • Endothelium, Vascular / physiopathology*
  • Female
  • Humans
  • Male
  • Mandibular Advancement*
  • Middle Aged
  • Single-Blind Method
  • Sleep Apnea, Obstructive / physiopathology
  • Sleep Apnea, Obstructive / therapy*
  • Treatment Outcome

Associated data

  • ClinicalTrials.gov/NCT01426607