Evaluation of permeability, doxorubicin delivery, and drug retention in a rat brain tumor model after ultrasound-induced blood-tumor barrier disruption

J Control Release. 2017 Mar 28:250:77-85. doi: 10.1016/j.jconrel.2016.10.011. Epub 2016 Oct 11.

Abstract

Drug delivery in brain tumors is challenging because of the presence of blood-brain barrier (BBB) and the blood-tumor barrier (BTB). Focused ultrasound (FUS) combined with microbubbles can enhance the permeability of the BTB in brain tumors, as well as disrupting the BBB in the surrounding tissue. In this study, dynamic contrast-enhanced Magnetic Resonance Imaging (DCE-MRI) was used to characterize FUS-induced permeability changes in a rat glioma model and in the normal brain and to investigate the relationship between these changes and the resulting concentration of the chemotherapy agent doxorubicin (DOX). 9L gliosarcoma cells were implanted in both hemispheres in male rats. At day 10-12 after implantation, FUS-induced BTB disruption using 690kHz ultrasound and Definity microbubbles was performed in one of the tumors and in a normal brain region in each animal. After FUS, DOX was administered at a dose of 5.67mg/kg. The resulting DOX concentration was measured via fluorometry at 1 or 24h after FUS. The transfer coefficient Ktrans describing extravasation of the MRI contrast agent Gd-DTPA was significantly increased in both the sonicated tumors and in the normal brain tissue (P<0.001) between the two DCE-MRI acquisitions obtained before and after FUS, while no significant difference was found in the controls (non-sonicated tumor/normal brain tissue). DOX concentrations were also significantly larger than controls in both the sonicated tumors and in the normal tissue volumes at 1 and 24h after sonication. The DOX concentrations were significantly larger (P<0.01) in the control tumors harvested 1h after FUS than in those harvested at 24h, when the tumor concentrations were not significantly different than in the non-sonicated normal brain. In contrast, there was no significant difference in the DOX concentrations between the tumors harvested at 1 and 24h after FUS or in the concentrations measured in the brain at these time points. The transfer coefficient Ktrans for Gd-DTPA and the drug concentrations showed a good linear correlation (R2=0.56). Overall, these data suggest that FUS and microbubbles can not only increase DOX delivery across the BBB and BTB, but that it is retained in the tissue at significantly enhanced levels for at least 24h. Such enhanced retention may increase the potency of this chemotherapy agent and allow for reduced systemic doses. Furthermore, MRI-based estimates of Gd-DTPA transport across these barriers might be useful to estimate local DOX concentrations in the tumor and in the surrounding normal tissue.

Keywords: Blood-brain barrier disruption; Dynamic contrast enhance MRI; Focused ultrasound; Pharmacokinetic model.

Publication types

  • Research Support, Non-U.S. Gov't
  • Research Support, N.I.H., Extramural

MeSH terms

  • Animals
  • Antineoplastic Agents / administration & dosage*
  • Antineoplastic Agents / metabolism
  • Blood-Brain Barrier / metabolism
  • Blood-Brain Barrier / radiation effects
  • Brain Neoplasms / blood supply
  • Brain Neoplasms / drug therapy*
  • Brain Neoplasms / metabolism
  • Cell Line, Tumor
  • Contrast Media
  • Delayed-Action Preparations
  • Doxorubicin / administration & dosage*
  • Doxorubicin / metabolism
  • Drug Delivery Systems
  • Drug Liberation
  • Gadolinium DTPA
  • Gliosarcoma / blood supply
  • Gliosarcoma / drug therapy*
  • Gliosarcoma / metabolism
  • Humans
  • Male
  • Microbubbles
  • Permeability
  • Rats
  • Rats, Sprague-Dawley
  • Ultrasonic Waves

Substances

  • Antineoplastic Agents
  • Contrast Media
  • Delayed-Action Preparations
  • Doxorubicin
  • Gadolinium DTPA