Clinical and hemodynamic results after direct transcatheter aortic valve replacement versus pre-implantation balloon aortic valvuloplasty: A case-matched analysis

Catheter Cardiovasc Interv. 2017 Nov 1;90(5):809-816. doi: 10.1002/ccd.26671. Epub 2016 Aug 12.

Abstract

Objectives: To evaluate the safety and midterm hemodynamic results of direct transcatheter aortic valve replacement (TAVR) without pre-implantation balloon aortic valvuloplasty (BAV).

Background: BAV was considered a mandatory previous step in TAVR procedures.

Methods: A total of 339 consecutive patients who underwent transfemoral TAVR were prospectively selected. A 1:1 matching was conducted, pairing age, prosthesis type (self-expandable or balloon expandable) and size, and valve calcification grade (48% with moderate to severe valve calcification). Finally, 102 pairs (102 patients with previous BAV and 102 without BAV) were obtained.

Results: Direct TAVR was feasible in all patients without any crossover to BAV group. Device success was achieved in 91.2% and 90.2% of cases in direct TAVR and pre-BAV groups (P = 0.810), respectively, without any differences in balloon postdilation rate and residual aortic regurgitation. The amount of contrast agent, acute kidney injury and myocardial injury was significantly lower in the direct implantation group (P < 0.05). No differences were found in 30-day and 1-year mortality between both groups (4.9% vs. 9.8%, P = 0.177 and 14.0% vs. 23.8%, P = 0.771, respectively). Hemodynamic parameters remained stable after 1-year follow-up in both groups.

Conclusions: Direct transfemoral TAVR without prior BAV was safe in patients with calcified severe aortic stenosis. Pre-implantation BAV could be omitted in patients undergoing TAVR, without influence in procedure success rate, and subsequent patients' clinical course and valve hemodynamic performance. © 2016 Wiley Periodicals, Inc.

Keywords: TAVI; TAVR; balloon aortic valvuloplasty predilation; postdilation; transcatheter aortic valve replacement.

Publication types

  • Comparative Study

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Valve / diagnostic imaging
  • Aortic Valve / pathology*
  • Aortic Valve / physiopathology
  • Aortic Valve / surgery*
  • Aortic Valve Stenosis / diagnostic imaging
  • Aortic Valve Stenosis / mortality
  • Aortic Valve Stenosis / physiopathology
  • Aortic Valve Stenosis / surgery*
  • Balloon Valvuloplasty* / adverse effects
  • Balloon Valvuloplasty* / mortality
  • Calcinosis / diagnostic imaging
  • Calcinosis / mortality
  • Calcinosis / physiopathology
  • Calcinosis / surgery*
  • Female
  • Heart Valve Prosthesis
  • Hemodynamics*
  • Humans
  • Kaplan-Meier Estimate
  • Male
  • Prospective Studies
  • Prosthesis Design
  • Recovery of Function
  • Risk Factors
  • Severity of Illness Index
  • Time Factors
  • Transcatheter Aortic Valve Replacement* / adverse effects
  • Transcatheter Aortic Valve Replacement* / instrumentation
  • Transcatheter Aortic Valve Replacement* / mortality
  • Treatment Outcome
  • Unnecessary Procedures

Supplementary concepts

  • Aortic Valve, Calcification of