A rapid and reliable technique for N-nitrosodimethylamine analysis in reclaimed water by HPLC-photochemical reaction-chemiluminescence

Chemosphere. 2016 Oct:161:104-111. doi: 10.1016/j.chemosphere.2016.06.094. Epub 2016 Jul 13.

Abstract

A fast and reliable analytical technique was evaluated and validated for determination of N-nitrosodimethylamine (NDMA) formation and rejection by reverse osmosis (RO) membranes in potable water reuse applications. The analytical instrument used in this study is high-performance liquid chromatography (HPLC), photochemical reaction (PR) and chemiluminescence (CL) - namely HPLC-PR-CL. Results reported here show that HPLC-PR-CL can be used to measure NDMA with a similar level of accuracy compared to conventional and more time-consuming techniques using gas chromatography and tandem mass spectrometry detection in combination with solid phase extraction. Among key residual chemicals (i.e. monochloramine, hydrogen peroxide and hypochlorite) in reclaimed wastewater, hypochlorite was the only constituent that interfered with the determination of NDMA by HPLC-PR-CL. However, hypochlorite interference was eliminated by adding ascorbic acid as a reducing agent. Direct injection of ultrafiltration (UF)-treated wastewater samples into HPLC-PR-CL also resulted in an underestimation of the NDMA concentration possibly due to interference by organic substances in the UF-treated wastewater. Accurate determination of NDMA concentrations in UF-treated wastewater was achieved by reducing the sample injection volume from 200 to 20 μL, though this increased the method detection limit from 0.2 to 2 ng/L. In contrast, no interference was observed with RO permeate. These results suggest that RO membranes could remove part of substances that interfere with the NDMA analysis by HPLC-PR-CL. In addition, RO treatment experiments demonstrated that HPLC-PR-CL was capable of evaluating near real-time variation in NDMA rejection by RO.

Keywords: Chemiluminescence; N-nitrosamines; N-nitrosodimethylamine (NDMA); Potable water reuse; Real-time analysis; Reverse osmosis.

MeSH terms

  • Chromatography, High Pressure Liquid*
  • Dimethylnitrosamine / analysis*
  • Dimethylnitrosamine / chemistry
  • Drinking Water / analysis
  • Environmental Monitoring / methods*
  • Filtration
  • Hydrogen Peroxide / chemistry
  • Luminescence
  • Solid Phase Extraction
  • Tandem Mass Spectrometry
  • Ultrafiltration / methods
  • Wastewater / analysis
  • Water Pollutants, Chemical / analysis*
  • Water Purification / methods

Substances

  • Drinking Water
  • Waste Water
  • Water Pollutants, Chemical
  • Hydrogen Peroxide
  • Dimethylnitrosamine